Ds230_03a_oi_e.doc / Jun-15
Page 40 / 100
6.10.
„Operational Mode“ = 4
Mode
4
Sensor1
[X10 | CONTROL IN]
Incremental HTL encoder
(A, B, 90°)
Sensor2
[X10 | CONTROL IN]
Incremental HTL encoder
(A) single channel
Control1
Control signal input not available
Control2
Control signal input not available
Achievable
Safety Level
Speed
SIL3 / PLe
Direction
SIL3 / PLe ****
Standstill
SIL3 / PLe ****
**** A safety level can only be achieved in these cases, if it is physically ensured that
there only can be only one direction of rotary and linear movement. This can be realized for
example by using a self-locking gearbox.
This mode (only DS23x) allows to evaluate a dual channel system, equipped with two different
encoder types. Therefor a combination of an incremental dual channel HTL encoder as well as a
single channel HTL encoder is used. The connections of both encoders must be performed in
accordance to chapter
A DS230 variant reproduces selectively the input frequency of Sensor1 or Sensor2
to the splitter output [X4 | RS422 OUT].
The inputs at [X6 | SINCOS IN 1], [X7 | SINCOS IN 2], [X8 | RS422 IN 1] und [X9 |
RS422 IN 2] have no function.
Please note, that no more Control1 and Control2 inputs for external commands are
available, when connecting both encoders to terminal X10] pin 2, 3 and 4.
Содержание DS230 Series
Страница 10: ...Ds230_03a_oi_e doc Jun 15 Page 10 100 4 3 DS236 Block Diagram 4 4 DS236 Connections...
Страница 11: ...Ds230_03a_oi_e doc Jun 15 Page 11 100 4 5 DS240 Block Diagram 4 6 DS240 Connections...
Страница 12: ...Ds230_03a_oi_e doc Jun 15 Page 12 100 4 7 DS246 Block Diagram 4 8 DS246 Connections...
Страница 99: ...Ds230_03a_oi_e doc Jun 15 Page 99 100 11 1 Dimensions inclusive BG230 at front Front Rear DS230 BG230 option...
Страница 100: ...Ds230_03a_oi_e doc Jun 15 Page 100 100 12 Certificate...