Ds230_03a_oi_e.doc / Jun-15
Page 86 / 100
8.6.
Sensor Channel Adaption
When using two sensors with a different number of pulses or in case of a mechanical speed
reduction between both encoders, then the higher frequency must be adjusted to the lower one. For
this calculation the scaling factors (see chapter
are used.
In the example above the frequency 2 is smaller by the factor 0.0994 than frequency 1.
For adjustment, the “Multiplier 1” (parameter 014) should be set to 994 and the “Divisor 1”
(parameter 015) to 10.000.
Содержание DS230 Series
Страница 10: ...Ds230_03a_oi_e doc Jun 15 Page 10 100 4 3 DS236 Block Diagram 4 4 DS236 Connections...
Страница 11: ...Ds230_03a_oi_e doc Jun 15 Page 11 100 4 5 DS240 Block Diagram 4 6 DS240 Connections...
Страница 12: ...Ds230_03a_oi_e doc Jun 15 Page 12 100 4 7 DS246 Block Diagram 4 8 DS246 Connections...
Страница 99: ...Ds230_03a_oi_e doc Jun 15 Page 99 100 11 1 Dimensions inclusive BG230 at front Front Rear DS230 BG230 option...
Страница 100: ...Ds230_03a_oi_e doc Jun 15 Page 100 100 12 Certificate...