Ds230_03a_oi_e.doc / Jun-15
Page 34 / 100
6.4.
Achievable Safety Level of DS24x
To achieve a maximum of SIL3/PLe on system-level, a SIL3/PLe certificated sensor is required to fulfil
the integrity of the device. The required safety level (by complying the safety-related characteristics SFF,
HFT, Type A/B, PFH, PFD resp. category, DCavg and MTTFd) and systematic safety integrity must be
ensured for the entire protection circuit.
Software programs (like SISTEMA) are very helpful for creating such evaluations of safety-related
machine control systems according to the EN ISO 13849 norm.
Mode Sensor1
Sensor2
Function
Achievable
Safety Level
0
SIL3/PLe SinCos encoder
[X6 | SINCOS IN 1]
Sensor1 and Sensor2 are
internally bridged
Speed
Direction
Standstill
SIL3 / PLe
SIL3 / PLe
SIL3 / PLe