8.4.
Checklist for Parameter Settings
General settings:
1.
Does Parameter 000 (Operational Mode) correspond to the selected encoder types?
2.
Are correct preset values defined in the „Preselection Menu“ (Parameter 027, et seq.)?
3.
Are all outputs and relays adjusted in accordance to the demanded switching conditions?
(see chapter …)
Optional settings:
1.
Are the switching characteristics and command assignments for the HTL inputs defined?
2.
Is the source input for the RS422 splitter output selected (see parameter 074)?
3.
Is the analog output scaled with a start- and an end-value (see parameter 078, 079)?
8.5.
Definition of the Directions
In order to define the directions, the machine must move resp. turn to its working direction. The
frequencies of sensor 1 and 2 are indicated in the “Monitor” window of the operator surface. The
direction of each frequency can be changed by setting the respective „Direction“ Parameter (see
parameter 013 resp. 020).