Page 73 / 100
Continuation „Control Menu“
No. Parameter
Range
Default
063 Input 1 Config
(switching condition of input Control1)
:
0
static function,
active LOW: [X10:2] = Lo, [X10:3] = Hi
1
static function,
active HIGH: [X10:2] = Hi, [X10:3] = Lo
2
dynamic function,
active when moving from HIGH to LOW [X10:2]
and simultaneously moving from LOW to HIGH [X10:3]
3
dynamic function,
active when moving from HIGH to LOW [X10:2]
and simultaneously moving from LOW to HIGH [X10:3]
0 - 3
0
064 Input 2 Function
(assigns a control function to input Control2)
:
Identical functions to Parameter 062, but for input Control2
0 - 16
0
065 Input 2 Config
(switching condition of the input Control2)
:
Identical functions to Parameter 063, but for input Control2
0 - 3
0
066 Reserved
067 Reserved