6.6.
„Operational Mode“ = 0 (DS24x)
Mode
0
Sensor1
[X6 | SINCOS IN 1]
SinCos encoder
(SIN+, SIN-, COS+, COS-)
Sensor2
Sensor1 and Sensor2 are internally bridged
Control1
[X10 | CONTROL IN]
HTL/PNP control signal
(complementary)
Control2
[X10 | CONTROL IN]
HTL/PNP control signal
(complementary)
Achievable
Safety Level
Speed
SIL3 / PLe
Direction
SIL3 / PLe
Standstill
SIL3 / PLe
This mode (only DS24x) is exclusively used to connect a SIL3 resp. PLe certificated SinCos sensor
/encoder, which must be performed in accordance to chapter
5.3
.
In this operational mode a DS240 variant reproduces always the input frequency at
[X6 | SINCOS IN 1] to the splitter outputs [X4 | RS422 OUT] and [X5 | RS422 OUT].
At terminal [X10 | CONTROL IN] the inputs Control1 and Control2 are available
for control signals.