Ds230_03a_oi_e.doc / Jun-15
Page 30 / 100
5.14.
LEDs / Status Indication
Two status LEDs are located at the front of the unit. The green one is marked as [ON] and the yellow
one as [ERROR].
Status LEDs
The green status LED uses the following two conditions:
LED (green)
Condition
OFF
Power off - no power supply voltage
ON
Power on - power supply voltage is ok
The yellow status LED uses the following four conditions:
LED (yellow)
Condition
OFF
Normal operation, self-test successfully completed, no error messages
ON
After power on: the unit is running up, self-test in progress
During normal operation: error released by the process (divergence of frequencies etc.)
SLOW
DIL1 = OFF: unit-state „Factory Settings“
DIL3 = OFF: unit-state „Programming Mode“
FAST
Error: incorrect self-test or internal error (see chapter
Error Detection)
OFF = LED if off, ON = LED is lighting
SLOW = slow flashing (approx. 1 Hz), FAST = fast flashing (approx. 2.5 Hz)
„Programming Mode“ (DIL switch) only for start-up
Set all (DIL switch) sliders to „ON“ after start-up
Protect the (DIL switch) sliders after start-up (e. g. by covering with an adhesive tape)
Normal operation is only permitted when the yellow LED is permanently off
The safety function of the unit cannot be guaranteed before the commissioning is
completed.
Содержание DS230 Series
Страница 10: ...Ds230_03a_oi_e doc Jun 15 Page 10 100 4 3 DS236 Block Diagram 4 4 DS236 Connections...
Страница 11: ...Ds230_03a_oi_e doc Jun 15 Page 11 100 4 5 DS240 Block Diagram 4 6 DS240 Connections...
Страница 12: ...Ds230_03a_oi_e doc Jun 15 Page 12 100 4 7 DS246 Block Diagram 4 8 DS246 Connections...
Страница 99: ...Ds230_03a_oi_e doc Jun 15 Page 99 100 11 1 Dimensions inclusive BG230 at front Front Rear DS230 BG230 option...
Страница 100: ...Ds230_03a_oi_e doc Jun 15 Page 100 100 12 Certificate...