Ds230_03a_oi_e.doc / Jun-15
Page 54 / 100
Continuation “Main Menu”:
No.
Parameter
Range
Default
003
F1-F2 Selection
(Basic Frequency Selection)
:
Important notes for DS240 / DS246 see chapter
This Parameter determines, which of both input frequencies of sensor1
or sensor2 (see parameter 000) is monitored and processed as basic
frequency.
The basic frequency selection affects the following outputs:
-
Analog Output
-
Control Outputs
-
Relay Outputs
And thus the following menus:
- preselected thresholds in the Preselect Menu (see chapter
- switching behaviors in the Switching Menu (see chapter
- analog output in the Analog Menu (see chapter
0
Frequency of sensor1 serves as basic frequency
1
Frequency of sensor2 serves as basic frequency
0 - 1
0
Содержание DS230 Series
Страница 10: ...Ds230_03a_oi_e doc Jun 15 Page 10 100 4 3 DS236 Block Diagram 4 4 DS236 Connections...
Страница 11: ...Ds230_03a_oi_e doc Jun 15 Page 11 100 4 5 DS240 Block Diagram 4 6 DS240 Connections...
Страница 12: ...Ds230_03a_oi_e doc Jun 15 Page 12 100 4 7 DS246 Block Diagram 4 8 DS246 Connections...
Страница 99: ...Ds230_03a_oi_e doc Jun 15 Page 99 100 11 1 Dimensions inclusive BG230 at front Front Rear DS230 BG230 option...
Страница 100: ...Ds230_03a_oi_e doc Jun 15 Page 100 100 12 Certificate...