49
10.4.
–
Name the System
10.4.1. - The Unit can be given a name (ID) which is included with all
messages it sends. The name can be up to 32 characters long
10.4.2. - To name the system send the following message (In the example
below the system has been named “Myboat”):
-
10.4.2.1. -
Secret, name, Myboat
10.4.3. - To check the system name send the following message: -
10.4.3.1. -
Secret, name
10.5.
–
Configure Overspeed Alarm
10.5.1. - The Unit can be set to inform if a defined speed limit is breached
10.5.2. - To set this speed limit send the following message (In the example
below the speed has been set at 6 knots): -
10.5.2.1. -
Secret, speed, 6
10.5.3. - To check the system speed limit send the following message: -
10.5.3.1. -
Secret, speed
10.5.4.
–
When the boat maintains a speed above the limit for greater than
30 seconds all phones set with the Monitor Triggered event code will
receive an overspeed message.
10.6.
–
To reset the Control Unit
10.6.1. - To restore factory (default) settings send the unit the following
message: -
10.6.1.1. -
Secret, reset
10.6.2. -
N.B. THIS WILL DELETE AL OF YOUR SETTINGS
Содержание TAD-214-W300
Страница 1: ...Monitor Installation Instructions and Operating Manual...
Страница 2: ......
Страница 3: ...Monitor Installation Instructions and Operating Manual Applicable to Firmware version 1 0 to 5 0...
Страница 4: ......
Страница 23: ...19 4 12 2 Connect POSITIVE RED wire to terminal H Speaker NEGATIVE BLACK wire to terminal I Speaker...
Страница 64: ...60 14 Wiring Diagram Monitor Control Unit...
Страница 65: ...61 Monitor Control Unit Detail View 1...
Страница 66: ...62 Monitor Control unit Detail View 2...
Страница 67: ...63 14 1 Supplementary Wiring Diagrams 14 1 1 Shore Power Sensor...
Страница 68: ...64 14 1 2 Switching Relay...
Страница 69: ...65 14 1 2 a Switching Relay 2 way switching...
Страница 70: ...66 14 1 3 Protecting Relay...
Страница 76: ...72 Notes...
Страница 77: ...73 Notes...
Страница 78: ...74 Notes...
Страница 79: ......