35
7.7 - Set Up Phones
7.7.1. - The Monitor system can be set up to report to up to 10 Phones
(
monitor III
), 5 Phones (
monitor II
) & 3 Phones (
monitor I
). The system can be set
to send combinations of specific information or all information on a
number by number basis. When choosing which Phones the system will
report to consider the following as a minimum:
7.7.1.1. - The phone must be capable of receiving text messages.
7.7.1.2. - Ideally it must also be able to send text messages.
7.7.1.3. - Mobile phones may suffer signal problems so selecting
phones likely to be in different locations improves likelihood of a
quick receipt of any alarms.
7.7.1.4. - Mobiles can be switched off - if all registered phones are
off any alarm will not be received.
7.7.1.5. - Alarms may occur at night as well as in the day.
7.7.1.6. - Reliability of phone owner.
7.7.2. - There are 7 types/groups of messages that the Monitor system will
send, these are called ‘events’ and are; Status, Low Battery, Alarm Arm,
Alarm Disarm, GeoFenced Triggered, Monitor Triggered, Alarm Triggered.
7.7.3. - Which messages each of the phones receive is determined by its
‘event mask’. An ‘event mask’ is a number ranging from 0 to 127 and is
calculated by adding together the event codes for the required messages,
detailed in table 7.7.3.1.: -
Table 7.7.3.1.
Event (message)
Event Code
Status Message
1
Low Battery
2
Alarm Arm
4
Alarm Disarm
8
GeoFence Triggered
16
Monitor Triggered
32
Alarm Triggered
64
7.7.3.2. - For example the event mask required to receive
messages when the alarm is triggered, automatic status messages
and messages when the battery is low would be 67 (64+1+2).
Содержание TAD-214-W300
Страница 1: ...Monitor Installation Instructions and Operating Manual...
Страница 2: ......
Страница 3: ...Monitor Installation Instructions and Operating Manual Applicable to Firmware version 1 0 to 5 0...
Страница 4: ......
Страница 23: ...19 4 12 2 Connect POSITIVE RED wire to terminal H Speaker NEGATIVE BLACK wire to terminal I Speaker...
Страница 64: ...60 14 Wiring Diagram Monitor Control Unit...
Страница 65: ...61 Monitor Control Unit Detail View 1...
Страница 66: ...62 Monitor Control unit Detail View 2...
Страница 67: ...63 14 1 Supplementary Wiring Diagrams 14 1 1 Shore Power Sensor...
Страница 68: ...64 14 1 2 Switching Relay...
Страница 69: ...65 14 1 2 a Switching Relay 2 way switching...
Страница 70: ...66 14 1 3 Protecting Relay...
Страница 76: ...72 Notes...
Страница 77: ...73 Notes...
Страница 78: ...74 Notes...
Страница 79: ......