15
4.2.3.4. - Any monitoring sensors such as bilge level, smoke detector,
Shore Power can be connected to either channels 13 or 14.
4.3. - It is essential that the correct cabling is used; oversized could result
in problems in terminations, undersize may not carry the load or result in
signal loss. For power and sensors requiring only 2 wires we recommend
the use of 2core 0.5mm
2
cable, for sensors requiring more than 2 wires we
recommend the use of standard 4 core alarm cable.
4.4. - The GSM and GPS antenna connectors on the Monitor Control Unit
standard enclosures are located on the external left hand side of the case;
Monitor Rugged enclosure has them mounted inside the case. The
connectors are polarised so they cannot be incorrectly fitted. The Wireless
RF antenna is externally mounted below the GSM/GPS connectors on
standard enclosures, and on the top of the Rugged enclosure.
4.5. - Power Supply
4.5.1. - Monitor systems are available in 12V (a 24V version is available at a
supplement).
Ensure that you are using the correct version for the
supply voltage in use.
4.5.2. - The supply should be fused at 5A. If a Monitor kit has been
purchased, a wiring loom with an inline fuse folder will have been
supplied. The fuse should be mounted as near to the battery as possible so
that the whole cable run is protected.
The power must not be switched on during installation or whilst any
connection/disconnection is made (This includes disconnection of the
internal Battery).
The Power must not be switched on during fitting or removal of the
SIM card (This includes disconnection of the internal Battery).
4.5.3. - Connect: -
0V / GROUND / BLACK wire to terminal A (SUPPLY-).
+12V / RED wire to terminal B ().
Содержание TAD-214-W300
Страница 1: ...Monitor Installation Instructions and Operating Manual...
Страница 2: ......
Страница 3: ...Monitor Installation Instructions and Operating Manual Applicable to Firmware version 1 0 to 5 0...
Страница 4: ......
Страница 23: ...19 4 12 2 Connect POSITIVE RED wire to terminal H Speaker NEGATIVE BLACK wire to terminal I Speaker...
Страница 64: ...60 14 Wiring Diagram Monitor Control Unit...
Страница 65: ...61 Monitor Control Unit Detail View 1...
Страница 66: ...62 Monitor Control unit Detail View 2...
Страница 67: ...63 14 1 Supplementary Wiring Diagrams 14 1 1 Shore Power Sensor...
Страница 68: ...64 14 1 2 Switching Relay...
Страница 69: ...65 14 1 2 a Switching Relay 2 way switching...
Страница 70: ...66 14 1 3 Protecting Relay...