Connecting the unit
53
Installation instructions
ATTENTION
Risk of physical damage from the wrong water quality
•
Ensure that the water quality complies with the equipment
and connection data.
ATTENTION
Risk of physical damage from dirt particles in the tap water
•
Ensure that a fine filter with a mesh size < 80 µm is installed
in the warm and cold water lines.
ATTENTION
Risk of physical damage from calcium deposits
Calcium can become deposited in the cleaning system.
•
The water hardness must be set when the unit is first
commissioned.
6.4.1 Connecting the tap water connection line
a
b
Image: Water connection
a Cold tap water connection
(marked blue)
b Warm tap water connection
(marked red)
Requirement
The tap water complies with the specifications (see "Equipment and
connection data")
Water hardness set (see "Equipment and connection data")
Fine filter with a mesh size < 80 μm installed
Backflow preventer installed
The connection lines are pressure-tight and suitable for tap water
Cover plate for service connections removed
1. Flush the connection lines thoroughly.
2. Insert dirt filters in the water connections.
10000008311AINBEB
Содержание FlexiChef FCEKMP12 Series
Страница 64: ...Putting the unit into service 64 Installation instructions 10000008311AINBEB ...
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ...www mkn com ...