Description of the unit
15
Installation instructions
Model
FCEKMP...
Size
X12XX...
X22XX...
X23XX...
X32XX...
X33XX...
MaxPower connected load (kW)
15.8
24.2
36.7
MaxPower fuse (A)
3 x 35
3 x 50
3 x 63
Voltage (V)
440
FlexPower connected load (kW)
---
---
---
FlexPower fuse (A)
---
---
---
MaxPower connected load (kW)
15
23
34.9
MaxPower fuse (A)
3 x 25
3 x 35
3 x 50
If both units of a Team unit are used at the same time, the values given in the individual columns are added together.
FlexPower = Output-reduced
Socket connection data
Socket
Type F
Type G
Type J
Type E
Country (for example)
Germany / EU
Great Britain
Switzerland
France
Separate supply connection
terminal (mm²)
2,5 mm²
Type of connection
1NPE
Voltage (V)
250
Fuse (A)
16
13
10
16
Pressure relief device
All models with high-speed cooking
Safety function
Connection (")
Response pressure
(kPa (bar))
Position
Pressure relief valve for cooking
zone
G 3/4
Maximum 49 (0,5)
Rear side arm, top
3.3.1 Basic control setting
Basic setting
Parameter
s
Standard
value
Adjustment
range
Explanation
Date/time
yyyy - mm - dd
Year - Month - Day
hh : mm
Hour : Minute
Setting water
hardness
5
1 — 9
The water hardness must be set when the
unit is first commissioned.
Determine the water hardness with the
relevant water authority.
Settings parameters
1. Set parameters via the roller.
2. Tap the "Read" button to display the
set value.
3. Specify another value via the button
panel.
4. Press the "Write" button to save the
new value.
10000008311AINBEB
Содержание FlexiChef FCEKMP12 Series
Страница 64: ...Putting the unit into service 64 Installation instructions 10000008311AINBEB ...
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ...www mkn com ...