Description of the unit
14
Installation instructions
Model
FCEKMP...
Size
X12XX...
X22XX...
X23XX...
X32XX...
X33XX...
Emissions
Noise level (db (A))
< 70
Heat output (operation as boiling kettle and cooking appliance)
MaxPower, latent / sensible (W)
2940 / 515
4480 / 784
6800 / 1190
FlexPower, latent / sensible (W)
2620 / 459
3440 / 602
5240 / 917
Heat output (operation as pressure cooking kettle)
MaxPower, latent / sensible (W)
147 / 588
224 / 896
340 / 1360
FlexPower, latent / sensible (W)
131 / 524
172 / 688
262 / 1048
Heat output (operation as tiltable frying pan)
MaxPower, latent / sensible (W)
5880 /
6615
8960 / 10080
13600 / 15300
FlexPower, latent / sensible (W)
5240 /
5895
6880 / 7740
10480 / 11790
Heat output (operation as deep-fat fryer)
MaxPower, latent / sensible (W)
10290 /
1323
15680 / 2016
23800 / 3060
FlexPower, latent / sensible (W)
9170 /
1179
12040 / 1548
18340 / 2358
The sensible and latent heat amounts are determined in Germany on the basis of VDI 2052 at a connection voltage of
400 V. Regulations applying in other regions may vary from this.
Power connection
Protection class
IPX6
Protection class for unit with socket
IPX4
Type of connection
3PE / AC 50/60 Hz, 3NPE / AC 50/60 Hz
Connection terminal (mm²)
50
Voltage (V)
380
FlexPower connected load (kW)
12.0
15.6
23.6
FlexPower fuse (A)
3 x 25
3 x 32
3 x 50
MaxPower connected load (kW)
13.3
20.3
30.7
MaxPower fuse (A)
3 x 35
3 x 50
3 x 63
Voltage (V)
400
FlexPower connected load (kW)
13.1
17.2
26.2
FlexPower fuse (A)
3 x 25
3 x 32
3 x 50
MaxPower connected load (kW)
14.7
22.4
34
MaxPower fuse (A)
3 x 35
3 x 50
3 x 63
Voltage (V)
415
FlexPower connected load (kW)
13.9
18.6
28.2
FlexPower fuse (A)
3 x 25
3 x 32
3 x 50