Connecting the unit
43
Installation instructions
Fault current device
Image: RCD switch type A, circuit symbol
The unit can be connected to a fault current device.
If a fault current device is used, a fault current device type A (RCD
type A) must be installed, to ensure that AC fault currents and
pulsating DC currents are detected.
A fault current protective device of 300 mA is to be provided for this
unit.
Potential equalisation
Image: Symbol for potential equalisation
The unit can be included in a potential equalisation system by means
of appropriately sized wiring.
Permanent connection
CAUTION
Risk of property damage and personal injury from improper
installation
•
In the case of a permanent electrical connection, install an
all-phase disconnect switch before the unit.
Install an all-phase disconnect switch if the unit will be connected
permanently to the electric mains.
10000008311AINBEB
Содержание FlexiChef FCEKMP12 Series
Страница 64: ...Putting the unit into service 64 Installation instructions 10000008311AINBEB ...
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ...www mkn com ...