Connecting the unit
56
Installation instructions
6.5.2 Connecting the wastewater connection to a waste trap in the building
ATTENTION
Risk of water escape if there is backing up in the
wastewater pipe
The water height within the waste trap must not be more than 50
mm mm.
The waste trap must lie below the wastewater connection of the
unit.
If a waste trap is installed in the wastewater system, a vacuum
breaker must be installed in the wastewater line.
a
b
c
e
d
Image: Wastewater line with waste trap in the building
a Wastewater connection
d Wastewater system trap
b Wastewater line
e Vacuum breaker
c Wastewater system
Requirement
Wastewater line complies with the specifications (see "Equipment
and connection data")
Cover plate for service connections removed
1. Unscrew the pipe clamp on the unit's wastewater connection.
2. Remove the waste trap from the unit.
3. Install the wastewater line up to the connection at the sewer
system.
4. Secure the wastewater line with pipe clamps.
5. Fill out the commissioning report.
10000008311AINBEB
Содержание FlexiChef FCEKMP12 Series
Страница 64: ...Putting the unit into service 64 Installation instructions 10000008311AINBEB ...
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ...www mkn com ...