1 - 13 1 - 13
MELSEC-Q
1 OVERVIEW
Function
QJ71C24N
(-R2/R4)
QJ71C24
(-R2)
Outline of function
Reference section
Addition of changeable data
to the user frame
(05
H
, 0B
H
, 11
H
, 17
H
)
Addition of changeable data
to the user frame
(04
H
, 0A
H,
E5
H,
EB
H
)
These functions allow the following codes to be registered as the
changeable data of user frames for data communication.
• Horizontal parity code
• Sum check code of two’s-complement number
User’s Manual
(Application)
Adding a reception function
through the use of user
frames
This function allows reception of a message consisting of the head frame
and any data field when receiving data by specifying the head frame.
The data length of the data field can be specified freely for each
combination of user frames for reception set by the user.
(Receiving 1 byte providing ACK/NAK only is also possible by setting the
data length of the data field to “0.”)
User’s Manual
(Application)
Multiple specification of
transparent codes for
transmission
This function allows specification of a maximum of 10 types of transparent
codes for transmission per interface when sending data using one of the
following protocols:
• Non procedure protocol
• Bidirectional protocol
User’s Manual
(Application)
Switching to the GX
Developer connection mode
by switching the mode
This function allows the GX Developer connection mode to be switched by
an external device or the programmable controller CPU.
User’s Manual
(Application)
Reference Manual
Communication data
monitoring function
This function allows the monitoring of communication data transmitted on
the communication network of the Q series C24 and an external device.
User’s Manual
(Application)
Operating Manual
(Protocol FB
support function)
UINI instruction
The UINI instruction allows change of the mode, transmission specifications
and host station No. of the Q series C24.
User’s Manual
(Application)
Specification of station
No.65 to 120 by MC protocol
(QnA compatible 4C/3C
frame only)
This function allows to access station No. 65 to 120 of the CC-Link IE
Controller Network, CC-Link IE Field Network.
Reference Manual
Access to link direct device
LW10000 or l higher using
MC protocol
(QnA compatible 4C/3C
frame only)
This function allows access to link direct device LW10000 or higher.
Reference Manual
Access to extended data
register D65536 or higher or
extended link register
W10000 or higher using MC
protocol (QnA compatible
4C/3C/2C frame only)
This function allows access to extended data register D65536 or higher and
extended link register W10000 or higher.
Reference Manual
Support for multiple CPU
system
This function allows access to the control/non-control CPUs specified by the
user when performing the following forms of data communication with a
multiple CPU system:
• Communication using the MC protocol
• QCPU access from GX Developer
Reference Manual
Data communication using
the pre-defined protocol
function
Data can be transferred with the protocol appropriate to the communication
target device.
Chapter 8,
Operating Manual
(Pre-defined
protocol support
function)
Содержание MELSEC QJ71C24
Страница 1: ......
Страница 2: ......
Страница 103: ...3 42 3 42 MELSEC Q 3 SPECIFICATIONS MEMO ...
Страница 177: ...6 33 6 33 MELSEC Q 6 DATA COMMUNICATION USING THE NON PROCEDURE PROTOCOL MEMO ...
Страница 397: ...App 24 App 24 MELSEC Q APPENDIXES Connection example 3 Connection example 4 ...
Страница 441: ......
Страница 442: ......