2 - 3 2 - 3
MELSEC-Q
2 SYSTEM CONFIGURATION AND AVAILABLE FUNCTIONS
(b) Mounting to a MELSECNET/H remote I/O station
The table below shows the network modules and base units applicable to
the Q series C24 and quantities for each network module model.
Depending on the combination with other modules or the number of
mounted modules, power supply capacity may be insufficient.
Pay attention to the power supply capacity before mounting modules, and if
the power supply capacity is insufficient, change the combination of the
modules.
Base unit
2
Applicable network
module
No. of modules
1
Main base unit of
remote I/O station
Extension base unit of
remote I/O station
QJ72LP25-25
QJ72LP25G
QJ72LP25GE
QJ72BR15
Up to 64
:
Applicable,
:
N/A
1 Limited within the range of I/O points for the network module.
2 Can be installed to any I/O slot of a base unit.
REMARKS
The Basic model QCPU module or C Controller module cannot create the
MELSECNET/H remote I/O network.
Pre-defined protocol communication is not available for MELSECNET/H remote I/O
stations.
(2) Support of the multiple CPU system
When using the Q series C24 in a multiple CPU system, refer to the QCPU
User’s Manual (Multiple CPU System) first.
(a) Compatible Q series C24
If using the Q series C24 on a multiple CPU system, use function version B
of the Q series C24.
(b) Intelligent function module parameters
Write intelligent function module parameters to only the control CPU of the
Q series C24.
Содержание MELSEC QJ71C24
Страница 1: ......
Страница 2: ......
Страница 103: ...3 42 3 42 MELSEC Q 3 SPECIFICATIONS MEMO ...
Страница 177: ...6 33 6 33 MELSEC Q 6 DATA COMMUNICATION USING THE NON PROCEDURE PROTOCOL MEMO ...
Страница 397: ...App 24 App 24 MELSEC Q APPENDIXES Connection example 3 Connection example 4 ...
Страница 441: ......
Страница 442: ......