9 - 40 9 - 40
MELSEC-Q
9 UTILITY PACKAGE (GX Configurator-SC)
[Test Items]
The following accumulated count of times counter values can be cleared to "0" by
the select test function.
Buffer memory address
Item
CH1 CH2
Reference section
Accumulated count of unlock process normal completion
22FB
H
Accumulated count of unlock process abnormal completion
22FC
H
Accumulated count of lock process based on circuit disconnection
22FF
H
Callback permit accumulated count
22F0
H
Callback denial accumulated count
22F1
H
Auto (callback) connection permit accumulated count
22F2
H
Auto (callback) connection denial accumulated count
22F3
H
Accumulated count of callback receive procedure cancel
22F4
H
User's Manual (Application)
[Operation procedure]
(Step 1) Display the "Modem function monitor/test" screen.
(Step 2) Click the setting value area of the item to be cleared to "0."
(Step 3) Click the " Execute test ."
The counter value of the selected item becomes "0."