3 - 35 3 - 35
MELSEC-Q
3 SPECIFICATIONS
Address
Decimal (Hex)
Applicable
protocol
CH1 CH2
Application Name
Initial
value
MC Non Bi Pd
Registration
Reference
section
8281 to
8361
(2059
H
to
20A9
H
)
8537 to
8617
(2159
H
to
21A9
H
)
For designation
of programmable
controller CPU
monitoring
function
Block
monitoring
devices No. 2
to 10
The structure of each area is the same as the first block monitoring device
area
See *1 for the details of each area.
Allowed
User's Manual
(Application)
8362 to
8421
(20AA
H
to
20E5
H
)
8618 to
8677
(21AA
H
to
21E5
H
)
Use prohibited
System area
—
8422
(20E6
H
)
8678
(21E6
H
)
Transmission pointer designation (for condition
agreement transmission and non-procedure data
transmission)
0: No designation
1 to 100: Output head point (send from nth)
Send the user frames designated in the following
transmission frame No. designation areas from
the designated pointer position.
(address: CH1 side = BA
H
to 11D
H
, CH2 side =
15A
H
to 1BD
H
)
Output count designation (for condition agreement
transmission and non-procedure data transmission)
8423
(20E7
H
)
8679
(21E7
H
)
0: No designation
1 to 100: Output count (designate the number of
frame transmissions)
—
R
Data No. for connection designation (for condition
agreement transmission and notification)
8424
(20E8
H
)
8680
(21E8
H
)
For designation
of programmable
controller CPU
monitoring
function
Programmable
controller CPU
abnormal
monitoring
designation
0: No designation
0BB8
H
to 0BD5
H
, 8001
H
to 801F
H
: Data No. for
connection
0
R
— Allowed
User's Manual
(Application)
8425 to
8447
(20E9
H
to
20FF
H
)
8681 to
8703
(21E9
H
to
21FF
H
)
Use prohibited
System area
—
8448 (2100
H
)
Use Prohibited
System area
—
8449 (2101
H
)
Data No. for callback designation 1
0BB8
H
to 0BD5
H
, 8001
H
to 801F
H
: Data number for callback.
8450 (2102
H
)
Data No. for callback designation 2
8451 (2103
H
)
Data No. for callback designation 3
8452 (2104
H
)
Data No. for callback designation 4
8453 (2105
H
)
Data No. for callback designation 5
8454 (2106
H
)
Data No. for callback designation 6
8455 (2107
H
)
Data No. for callback designation 7
8456 (2108
H
)
Data No. for callback designation 8
8457 (2109
H
)
Data No. for callback designation 9
8458 (210A
H
)
For callback
function
Data No. for callback designation 10
0
R
W
—
Allowed
Section 9.4.4
User’s Manual
(Application)
8704 to
8707
(2200
H
to
2203
H
)
8960 to
8963
(2300
H
to
2303
H
)
Use prohibited
System area
—
8708
(2204
H
)
8964
(2304
H
)
Programmable controller
CPU monitoring function operation status
0: Not executed (waiting for registration of programmable
controller CPU monitoring)
1: Wait for programmable controller CPU monitoring time
(waiting to access programmable controller CPU)
2: Accessing programmable controller CPU
3: Sending monitoring results
Programmable controller CPU monitoring function execution result
(current)
8709
(2205
H
)
8965
(2305
H
)
0: Normal completion
1 or more: Abnormal completion (error code)
Programmable controller CPU monitoring function number of
transmission
8710
(2206
H
)
8966
(2306
H
)
Programmable
controller CPU
monitoring
function
0: Not executed
1 or more: Number of transmissions
0 R — Not
allowed
User's Manual
(Application)
Содержание MELSEC QJ71C24
Страница 1: ......
Страница 2: ......
Страница 103: ...3 42 3 42 MELSEC Q 3 SPECIFICATIONS MEMO ...
Страница 177: ...6 33 6 33 MELSEC Q 6 DATA COMMUNICATION USING THE NON PROCEDURE PROTOCOL MEMO ...
Страница 397: ...App 24 App 24 MELSEC Q APPENDIXES Connection example 3 Connection example 4 ...
Страница 441: ......
Страница 442: ......