6 - 13 6 - 13
MELSEC-Q
6 DATA COMMUNICATION USING THE NON PROCEDURE PROTOCOL
4) The device completing the INPUT instruction turns ON when the reading of receive
data is completed.
When the complete 1 (abnormal completion signal) turns ON, the error
code is stored in the control data completion status (S1 + 1).
(Program example)
When the Q series C24 I/O signals are from X/Y00 to X/Y1F:
Data received prior to an error occurrence will be
stored in the receive data storage device.
For normal completion
(1)
(0)
(n)
(10)
(1)
(other than 0)
(n)
(10)
Q series C24
D 0
D 1
D 2
D 3
D10
D m
Interface number
Reception result
Receive data count
Allowable receive data count
Receive data
Receive data
For abnormal completion
D 0
D 1
D 2
D 3
D10
D x
Interface number
Reception result
Receive data count
Allowable receive data count
Receive data
Receive data
Buffer memory
Data reception result
Receive data count
Receive data
Address
258
H
600
H
601
H
7FF
H
When the receive data count is larger than the
allowable receive data count, only the data up to
the allowable receive data count will be stored
and the excess data will be discarded.
From the buffer memory (address 258
H
)
From the buffer memory (address 600
H
)
to
to
to
to
to
Содержание MELSEC QJ71C24
Страница 1: ......
Страница 2: ......
Страница 103: ...3 42 3 42 MELSEC Q 3 SPECIFICATIONS MEMO ...
Страница 177: ...6 33 6 33 MELSEC Q 6 DATA COMMUNICATION USING THE NON PROCEDURE PROTOCOL MEMO ...
Страница 397: ...App 24 App 24 MELSEC Q APPENDIXES Connection example 3 Connection example 4 ...
Страница 441: ......
Страница 442: ......