9 - 3 9 - 3
MELSEC-Q
9 UTILITY PACKAGE (GX Configurator-SC)
9.1 Functions Available with Utility Package
The following table lists the utility package function.
( : indicates that the setting is valid with the applicable protocol.)
Function MC
Non
procedure
protocol
Bidirectional
protocol
Pre-
defined
protocol
Explanation
page
Remarks
Auto refresh setting
Refresh the Q series C24's error codes and set devices on
the programmable controller CPU side.
Section 4.6
User frame
Register the user frame in the flash ROM.
— —
Section
9.4.1
Data for modem initialization
Register the data for modem initialization in the flash ROM.
— Section
9.4.2
Data for modem connection
Register the data for model connection in the flash ROM.
— Section
9.4.3
Modem function system setting
Register the system setting values for model function in the
flash ROM.
— Section
9.4.4
CHn Transmission control
and others system setting
Set the transmission specifications with the other device.
(DTR/DSR control, DC code control, communication
method, data communication monitoring timer value, etc.)
Section 9.4.5
CHn MC protocol system
setting
Assign the buffer memory for on-demand function, set the
user frame number, etc.
— —
—
Section 9.4.6
CHn Non procedure
system setting
Assign the buffer memory needed to perform data
communication using the non procedure protocol, and
change the setting values, etc.
—
—
—
Section 9.4.7
CHn Bidirectional system
setting
Assign the buffer memory needed to perform data
communication using the bidirectional protocol, and
change the setting values, etc.
—
—
— Section
9.4.8
CHn Pre-defined protocol
system setting
Change the set value for data communication using the
pre-defined protocol.
—
—
—
Section 9.4.9
CHn PLC CPU
monitoring system setting
Set the programmable controller CPU monitoring function.
—
—
Section 9.4.10
System
setting
CHn Transmission user
frame No. designation
system setting
Set the user frame number to be transmitted, etc.
—
—
—
Section 9.4.11
Can be
used via
online
operation.
Can be
used via
offline
operation.
System setting default
Reset the setting values in the buffer memory to their
default values.
Section 9.4.12
System setting write
Write the setting values in the buffer memory to the flash
ROM.
Section 9.4.12
Flash ROM write allow/prohibit
designation
Set whether to allow or prohibit writing to the flash ROM.
—
—
—
—
Section 9.4.13
X/Y monitor/test
Perform the monitoring/testing of I/O signals to/from the
programmable controller CPU.
Section 9.6.1
Modem function monitor/test
Monitor the execution status of the modem function.
— Section
9.6.2
CHn Transmission control
and others monitor/test
Monitor the status of interface control signals, values set
from the GX Developer, etc.
Section 9.6.3
CHn MC protocol monitor
—
—
—
Section 9.6.4
CHn Non procedure
monitor/test
—
—
—
Section 9.6.5
CHn Bidirectional monitor
—
—
—
Section 9.6.6
CHn Pre-defined protocol
monitor/test
Monitor the data communication result, I/O signal status,
and setting values in the buffer memory.
—
—
—
Section 9.6.7
CHn PLC CPU
monitoring monitor
Monitor the setting values and operating status of the
programmable controller CPU monitoring function.
—
—
Section 9.6.8
Monitor
CHn User frame No.
designation monitor for
transmission
Monitor the setting value for user frame to be transmitted.
—
—
Section 9.6.9
Monitor/test others
Monitor the data reception result, error occurrence status,
etc.
Section 9.6.10
ERR LED off
Turn off the ERR LEDs on the front face of the module.
Section 9.6.11
Non procedure protocol receive
data clear
Clear the currently received data.
—
—
—
Section 9.7
Can be
used only
via online
operation.
Содержание MELSEC QJ71C24
Страница 1: ......
Страница 2: ......
Страница 103: ...3 42 3 42 MELSEC Q 3 SPECIFICATIONS MEMO ...
Страница 177: ...6 33 6 33 MELSEC Q 6 DATA COMMUNICATION USING THE NON PROCEDURE PROTOCOL MEMO ...
Страница 397: ...App 24 App 24 MELSEC Q APPENDIXES Connection example 3 Connection example 4 ...
Страница 441: ......
Страница 442: ......