21
4.1 Flowchart of test run and adjustment
4. Adjustment and Initial Setting
4.
Adjustment and Initial Setting
4.1
Flowchart of test run and adjustment
• Before starting automatic operation, check and adjust the controller as follows.
4.2
Password setting
• In the adjustment mode, a password can be set for sifting to an adjustment/setting item selection screen.
• When a password is set, the password input screen is displayed when the power is turned ON in the
adjustment mode (DIP.SW8 is turned OFF). The screen cannot be moved to the adjustment/setting item
selection screen without inputting the password set in this screen.
4.2.1
Password setting
- - - - - - - Item number : 54
• In an adjustment mode (power ON with DIP. SW8 OFF), select item No.54 to set.
• When a password setting is not necessary, alteration from the default (=0) is not required.
On the adjustment/setting item selection screen, set the item number to
[54], and then press the
T
key.
Set the value on a password setting screen.
• Setting range - - - - -0 to 30000 - - - - Initial value=0
• As to the password, "4095" is predetermined. Thus, the value set through above-mentioned operation and
"4095" are effective as the password.
Installation and wiring
of controller.
Controller
• Setting DIP switches
• Adjustment of
tension detector
Drive system check
while performing
manual operation.
Operation check while
performing automatic
operation.
Adjustment of
operation parameters,
if necessary
Inspection after
occurrence of error
Refer to pages 46, 47
and 48.
Refer to pages 11 and 22.
Completion of
adjustment
(1)
(2)
(5)
(4)
(6)
(7)
(3)
Adjustment/setting
item selection screen