35
6.2 Analog input signals
6. Functions of Input/Output Signals
3) Taper rate setting signal
• Enter the signal to set the taper rate for taper control using the
external analog voltage.
• Reel diameter internal calculation method
- - - - - Input voltage = 0 to 5 V
→
Taper rate = 0 to 80%
• External reel diameter signal method
- - - - - Input voltage = 0 to 5 V
→
Taper rate = 0 to 100%
• When the taper rate setting signal function is assigned to the [AI1]
or [AI2], the taper rate cannot be set from using the setting dial(16)
on the panel.
4) Reel diameter signal
• Enter the reel diameter signal when the external reel
diameter signal method is used.
• Enter the voltage range 0 to 5V for the minimum diameter
to maximum diameter.
5) Manual output setting signals 1 and 2
• Set the manual output using the external analog voltage.
• For the input voltage range 0 to 5 V, the output range will be 0 to
100%.
• When the function of the manual output setting signal is
assigned to the [AI1] or [AI2], the manual output 1 or 2 cannot be
set using the value setting dial(16) on the panel.
6.2.2
Function setting
- - - - - - - - - - - - Item number : 51
• In the adjustment mode (power ON with DIP. SW8 OFF), select item number 51, and then set the function
of the analog input signal (AI1, AI2).
On the adjustment/setting item selection screen, select item number 51, and
then press the
T
key.
After selecting AI1 or AI2 with a screen selection keys (6) (
S
and
T
keys),
select a function for AI1 or AI2 using the setting dial(16), and then the
function is selected by pressing the [SET] key.
When the function already set is specified, the function will be displayed as
"UNAVAIL".
• From turning the dial(16), the following items will appear in the following order, and the displayed functions
are assigned to the [AI1] or [AI2].
(1) Tension setting signal
(2) External tension signal
(3) Taper rate setting signal
(4) Reel diameter signal
(5) Manual output setting signal 1
(6) Manual output setting signal 2
0
5
1
2
3
4
taper rate setting signal (V)
100
80
60
40
20
0
T
taper set r
a
te (
%
)
Reel diameter internal
calculation method
External reel diameter
signal method
Reel diameter
signal (V)
0
5
0
0.2
0.4
0.6
0.8
1.0
1
2
3
4
τ
=20%
τ
=40%
τ
=60%
τ
=80%
τ
=100%
Minimum
diameter
F(Target ten
s
ion)
Fo
(Set ten
sion)
Ttaper set rate
τ
= 0%
Maximum
diameter
0
5
1
2
3
4
Manual output setting signal (V)
Ma
nual output value (%)
100
80
60
40
20
0
Adjustment/setting
item selection screen
F4
1
Содержание LE-30CTN
Страница 1: ...MODEL LE 30CTN Conforming to CE Marking JZ990D33401D INSTRUCTION MANUAL ZJ 4049D ...
Страница 2: ......
Страница 4: ......
Страница 61: ...59 13 4 Measures for EMC 13 EC Directives CE Marking MEMO ...
Страница 63: ......
Страница 64: ...JZ990D33401D TENSION CONTROLLER MODEL LE 30CTN ...