15
3.1 Screen System
3. Screen system and method of change screen
3.
Screen system and method of change screen
3.1
Screen System
3.1.1
Overall of screen system
• The screens shown on the LCD display are shown below. To change screen, use the corresponding
function key (F1 through to F4 keys) or the screen selector keys (
S
and
T
keys).
Power-on
Operation mode
(When DIP switch 8 = ON)
Adjustment mode
(When DIP switch 8 = OFF)
When memory cassette
is inserted
Parameter initialization
(When DIP switch 7 = ON)
Screen displayed
turning off the power
in the operation mode
Manual
mode key
(13)
Automatic
mode key
(12)
F1
F2
F3
F4
Tension setting
screen
Manual Setting 1
screen
Manual Setting 2
screen
Taper rate setting
screen
Tension monitoring
screen (Total)
Tension monitoring
screen (Right, Left)
Extension screen
Use the function keys
to go to the desired
screen. The functions
of F1 through F4 keys
depend on the screen.
Password input screen
(Note)
Adjustment/setting item
selection screen
• F2
Auto zero
adjustment screen
• F1
Input/output
monitoring screen
• F3
Auto span
adjustment screen
• F4
Menu copy screen
F1
F2
F3
F4
[2] Go to the desired
screen by selecting
the corresponding
item number using
the value setting dial
(16) and then
pressing the
key.
[1] Go to the desired
screen using the
corresponding
function key.
Memory cassette
operation screen
Parameter initialization
screen
Operation completion
screen
Initialization
completion screen
F1
F4
After turning off the
power, remove the
memory cassette.
Then, turn on the
power.
Select the
operation
type.
Initializes the
parameter
After turning off the
power, turn off the DIP
switch 7, and turn on
DIP switch 8. After
that, turn on the power.
Execute
operation.
F1
F4
•
10:Stop timer,
Stop gain
•
11:Gain 1, gain 2
•
22:Manual zero
adjustment
•
23:Manual span
adjustment
•
30:Tension output
filter time constant
•
32:Low excitation
•
40:Proportional gain,
integral time
•
41:Additional gain,
addition dead band
width
•
50:Contact input of
MI1, MI2,MI3
•
51:Analog input of
AI1,AI2
•
52:Extension screen
setting
•
20:Full-scale tension,
Decimal point to
be indicated
•
21:Tension monitor
filter time constant
•
54:Pass word
setting screen
•
1:Tension setting
•
2:Manual Setting 1 ,2
•
3:Taper rate setting
Manual
mode key
(13)
Automatic
mode key
(12)
Operation mode screen
After turning off the power,
turn on DIP switch 8, and
then turn on the power.
•
26:Zero tension
detection
Priority order for screen selection at power-on.
(1) Memory cassette insertion screen
(2) Parameter initialization screen
(3) Adjustment mode screen
(Note) When a password setting value is
zero, a password input screen is
not displayed.