2.2 Wiring
2. Installation and Wiring
14
2.2.2
Basic wiring
- - - - - - - - - - - - - - - - - - - - - - - - For conformity to the CE marking, refer to Chapter 13.
• To control the tension using the LE-30CTN tension controller, perform at least the following wiring.
[1] Connect the AC power supply line of 100 ~ 240 VAC and 50 / 60 Hz between terminals L and N.
When maximum output between PP and PN is readed, the power consumption will be 400 VA.
[2] Perform grounding (grounding resistance 100
Ω
or less) to the grounding terminal and the metal plate.
[3] Connect the tension detector.
[4] If the powder clutch/brake or the hysteresis clutch/brake is used, connect the actuator between
terminals [PP] and [PN]. If the rated current of the powder clutch/brake is 3 A or more, connect the
[TOUT] - [AOC] signal line to the input terminal of the power amplifier that is optimum for the rated
current of the powder clutch/brake, and connect the powder clutch/brake to the output terminal of the
power amplifier.
If the torque controllable servomotor is used, connect the [TOUT] - [AOC] signal line to the torque
command terminal of the servo amplifier.
[5] Connect the start/stop signal line to the [RUN] and [MIC] terminals.
Caution:To perform automatic operation, be sure to turn the [RUN] input signal OFF and
ON according to the machine operation status (run or stop).
If this signal is kept at the ON status, restarting the operation of the stopped
machine may apply extremely strong tension to the material, and the material may
fracture.
• To use various functions, refer to Sec. 5 and subsequent sections.
2.2.3
Wiring of tension detector
[1] While ignoring the loading direction (compression or pulling), connect the cable of the tension
detector as shown in the above figure. The loading direction will be automatically detected.
[2] If only one tension detector is used, short-circuit the unused line between the input terminals ( [GRR]
and [WHR] or between [GRL] and [HWL] ).
• Do not connect any 380-VAC power line to the power supply terminals [L] and [N]. The product
may be seriously damaged.
24 VDC, 3 A or less
Powder clutch / brake
Hysteresis clutch / brake
MC1
DC0 to 5V
Servo amplifier
Power amplifier
Grounding resistance
100
Ω
or less
RUN / STOP
LE-30CTN
Green
White
Red
Black
5V
FG
8V
Tension detector
(Right)
Tension detector
(Left)
L
PP
PN
TOUT
AOC
MIC
RUN
RED
BLK
S G
S G
GRL
WHL
GRR
WHR
N
Connect one of the
following actuators.
Power supply
AC100 to 240V
50 / 60Hz
+10%
-15%
Green
White
CAUTION
Do not connect any
380-VAC power line to
the power supply
terminals [L] and [N].
The product may be
seriously damaged.