25
4.4 Automatic operation check
4. Adjustment and Initial Setting
4.4
Automatic operation check
• Basic setting for automatic operation is completed when the full-scale tension value is set and the zero point
and span of the tension detector are adjusted. Turn ON DIP switch 8 (to enter the operation mode), and then
check basic operation while following the procedure below.
4.4.1
Drive system operation check in manual operation mode
1) Turn on the power.
→
The power indicator LED(3) will light.
2) Press the manual control mode selection key(13) to enter the manual mode.
→
The MANUAL indicator lamp(10) will light, and the manual setting 1 screen will appear.
3) Start the machine, and check operation while changing the set manual output value using the value setting
dial(16).
[1] Check operation of the machine.
[2] Check that the tension monitoring graph shown on the LCD and the monitor value shown on the
monitor display(7) vary depending on the change to the set value.
[3] Check other operations.
4.4.2
Operation check in automatic operation mode
1) Turn on the power.
→
The POWER indicator LED(3) will light.
2) Press the automatic control mode selection key(12) to enter the automatic mode.
→
The AUTO indicator LED(13) will light, and the tension setting screen will appear.
3) Start the machine, and then turn ON the [RUN] input signal to start automatic operation. Check operation
while changing the set tension value using the value setting dial.
[1] On the LCD display(5), check that the tension monitoring graph is positioned at the same point as the
set tension graph.
[2] Check that the set tension value displayed on the LCD display(5) is equal to the monitored tension
value displayed on the monitor display(7).
[3] Check that changing the set tension value can vary the other values displayed.
[4] Check other operations.
Caution: To perform automatic operation, be sure to turn the [RUN] input signal OFF and
ON according to the machine operation status (run or stop).
If this signal is kept at the ON status, restarting the operation of the stopped
machine may apply extremely strong tension to the material, and the material may
fracture.
Set manual output value
Tension monitoring graph
Target tension graph
Shows the target tension value
at automatic control mode.
Tension monitoring graph
Target tension graph
Set tension value
Содержание LE-30CTN