2.1 Installation
2. Installation and Wiring
12
2.
Installation and Wiring
2.1
Installation
• The LE-30CTN should be installed in a conductive control box to achieve conformity to the CE marking.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Refer to Chapter 13.
• The tension controller can be floor, wall or panel mounted.
• Never drop cutting chips or wire chips while screw holes are tapped and wiring work is performed.
Otherwise, damage, fume, fire, malfunction or other may be caused in the unit.
• Make sure to turn off all the phases of the power supplies outside before starting installation and wiring.
Otherwise, electric shock or serious damage to the unit may occur.
• Never install the controller in a environment with dust, soot, conductive dusts or corrosive gas or a place
that is exposed to high temperature, condensation, wind or rain. Never install the unit directly in a place
in which vibration or impact is applied.
Otherwise, damage, malfunction or deterioration may be caused.
• Never mount the controller with the front surface face pointing upwards.
• When you install the controller to the floor or wall, be sure to use the screws supplied with the controller
to fix the plate to the controller main body. If you use screws 10 mm or longer, the screws may contact
the inner parts of the controller main body.
Screw tightening torque = 0.5 to 0.8 N
•
m.
• Using a screw hole where no screw is tightened to fix the mounting plate, perform grounding (grounding
registance 100
Ω
or less) of the sheet metal area.
256
168
Floor mounted
12 or
less
172.5
.
Wall mounted
244
+3
- 0.5
80
±0.5
4-M4 Screw
232±0.5
150±0.5
4 or less
*
Metal plate
140
Installed on Panel
28.5
or
less
Tighten screws to
press-fit the back of
the controller to the
panel.
4-M4×12
Mounting screw
Dimensions of screw holes
for floor or wall mounting.
Panel cutting dimensions
for panel mounting
Perform grounding (grounding
registance 100
Ω
or less) either
position marked with
½
in
which the main unit mounting
plate is not fixed.