8 - 15 8 - 15
MELSEC-Q
8 OPR CONTROL
Precaution during operation
(1) If "OPR. 8 Setting for the movement amount after near-point dog ON" is less
than the deceleration distance from "OPR. 4 OPR speed" to "OPR. 5 Creep
speed", OPR control is completed normally.
(2) When the near-point dog is ON, starting the axis will cause the "Start during
near-point dog ON" error (error code: 201). Perform JOG operation to move the
axis to the position where the near-point dog turns OFF.
(3) If the axis stop signal is turned ON during operation performed at "OPR. 4
OPR speed", the axis decelerates to a stop at the time set in "OPR. 7 DEC/
STOP time at OPR".
Содержание GX Configurator-PT
Страница 13: ...MEMO SECTION 1...
Страница 127: ...7 20 7 20 MELSEC Q 7 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO...
Страница 129: ...MEMO SECTION 2...
Страница 221: ...Index 5 Index 5 MEMO...