App - 16 App - 16
MELSEC-Q
APPENDIX
Appendix 9 List of buffer memory addresses
Buffer memory address
Axis 1 Axis 2 Axis 3 Axis 4 Axis 5 Axis 6 Axis 7 Axis 8
Item
Memory area
0
1
100
101
200
201
300
301
400
401
500
501
600
601
700
701
Pr. 1 Software stroke limit upper limit value
2
3
102
103
202
203
302
303
402
403
502
503
602
603
702
703
Pr. 2 Software stroke limit lower limit value
4
104
204
304
404
504
604
704
Pr. 3 Software stroke limit valid/invalid setting
5
105
205
305
405
505
605
705
Pr. 4 Current feed value during speed control
6
7
106
107
206
207
306
307
406
407
506
507
606
607
706
707
Pr. 5 Speed limit value
8
9
108
109
208
209
308
309
408
409
508
509
608
609
708
709
Pr. 6 Bias speed at start
10
110
210
310
410
510
610
710
Pr. 7 Positioning complete signal output time
11
111
211
311
411
511
611
711
Pr. 8 Deviation counter clear signal output time
12
112
212
312
412
512
612
712
Pr. 9 PULSE/SIGN method selection setup/hold time
13
113
213
313
413
513
613
713
Pr. 10 Stop mode during path control
Pa
ra
m
e
te
r
14
to
19
114
to
119
214
to
219
314
to
319
414
to
419
514
to
519
614
to
619
714
to
719
Reserved (Cannot be used)
20
120
220
320
420
520
620
720
OPR. 1 OPR method
21
121
221
321
421
521
621
721
OPR. 2 OPR direction
22
23
122
123
222
223
322
323
422
423
522
523
622
623
722
723
OPR. 3 OP address
24
25
124
125
224
225
324
325
424
425
524
525
624
625
724
725
OPR. 4 OPR speed
26
27
126
127
226
227
326
327
426
427
526
527
626
627
726
727
OPR. 5 Creep speed
28
128
228
328
428
528
628
728
OPR. 6 ACC/DEC time at OPR
29
129
229
329
429
529
629
729
OPR. 7 DEC/STOP time at OPR
30
31
130
131
230
231
330
331
430
431
530
531
630
631
730
731
OPR. 8 Setting for the movement amount after near-point
dog ON
32
132
232
332
432
532
632
732
OPR. 9 OPR dwell time
OP
R dat
a
33
to
39
133
to
139
233
to
239
333
to
339
433
to
439
533
to
539
633
to
639
733
to
739
Reserved (Cannot be used)
40
41
140
141
240
241
340
341
440
441
540
541
640
641
740
741
JOG. 1 JOG speed
42
142
242
342
442
542
642
742
JOG. 2 JOG ACC time
43
143
243
343
443
543
643
743
JOG. 3 JOG DEC time
44
144
244
344
444
544
644
744
JOG. 4 JOG direction flag
J
OG dat
a
45
to
49
145
to
149
245
to
249
345
to
349
445
to
449
545
to
549
645
to
649
745
to
749
Reserved (Cannot be used)
: Write to "Reserved (Cannot be used)" is prohibited.