3.3 Specifications of input/output signal with PLC CPU
3.3.1 List of input/output signals with PLC CPU
The QD70 uses 32 input points and 32 output points for exchanging data with the PLC
CPU.
The input/output signals when the QD70 is mounted in slot No. 0 of the main base unit
are shown below.
Device X refers to the signals input from the QD70 to the PLC CPU, and device Y
refers to the signals output from the PLC CPU to the QD70.
Signal direction: QD70
PLC CPU
Signal direction: PLC CPU
QD70
Device No.
Signal name
Device No.
Signal name
X0
Module READY
Y0
PLC READY
X1
Axis error occurrence
Y1
X2
Axis warning occurrence
Y2
X3
Y3
X4
Y4
X5
Y5
X6
Y6
X7
Use prohibited
Y7
Use prohibited
X8
Axis 1
Y8
Axis 1
X9
Axis 2
Y9
Axis 2
XA
Axis 3
YA
Axis 3
XB
Axis 4
YB
Axis 4
XC
Axis 5
YC
Axis 5
XD
Axis 6
YD
Axis 6
XE
Axis 7
YE
Axis 7
XF
Axis 8
BUSY
YF
Axis 8
Positioning start
X10
Axis 1
Y10
Axis 1
X11
Axis 2
Y11
Axis 2
X12
Axis 3
Y12
Axis 3
X13
Axis 4
Y13
Axis 4
X14
Axis 5
Y14
Axis 5
X15
Axis 6
Y15
Axis 6
X16
Axis 7
Y16
Axis 7
X17
Axis 8
Start complete
Y17
Axis 8
Axis stop
X18
Axis 1
Y18
Axis 1
X19
Axis 2
Y19
Axis 2
X1A
Axis 3
Y1A
Axis 3
X1B
Axis 4
Y1B
Axis 4
X1C
Axis 5
Y1C
Axis 5
X1D
Axis 6
Y1D
Axis 6
X1E
Axis 7
Y1E
Axis 7
X1F
Axis 8
Positioning complete
Y1F
Axis 8
JOG start
Important
[Y1 to Y7], and [X3 to X7] are used by the system, and cannot be used by the user.
If these devices are used, the operation of the QD70 will not be guaranteed.