13 - 6 13 - 6
MELSEC-Q
13 TROUBLESHOOTING
Related buffer memory address
Axis 1 Axis 2 Axis 3 Axis4 Axis 5 Axis 6 Axis 7 Axis 8
Setting range
Remedy
5
152
252
352
452
552
652
752
Cd. 3 Start method
0
: Positioning control
9000 : Machine OPR control
9001 : Fast OPR control
Set " Cd. 3 Start method" to within the
setting range (Refer to Section 4.7).
•
When " Da. 2 Control method" is
"Current value changing" or
"Speed.Position Ctrl.", do not set
"Continuous path control" in " Da. 1
Operation pattern".
•
Do not set "Current value changing" or
"Speed.Position Ctrl." in " Da. 2 Control
method" of the positioning data
following the positioning data where
"Continuous path control" has been set
in " Da. 1 Operation pattern".
(Refer to Section 9.2.3 and Section
9.2.4.)
Set " Da. 1 Operation pattern" to within
the setting range.
Set " Da. 5 Command speed" to other
than "0".
Set " Da. 2 Control method" to within the
setting range.
Set OPR. 6 , JOG. 2 , Da. 3 and Cd. 8
to within the setting range.
Set OPR. 7 , JOG. 3 , Da. 4 and Cd. 9
to within the setting range.
Refer to "Section 4.3 List of OPR data".
Refer to "Section 4.4 List of JOG data".
Refer to "Section 4.5 List of positioning data".
Refer to "Section 4.7 List of control data".
OPR. 6 ACC/DEC time at OPR
0 to 32767 (ms)
OPR. 7 DEC/STOP time at OPR
0 to 32767 (ms)
JOG. 2 JOG ACC time
0 to 32767 (ms)
JOG. 3 JOG DEC time
0 to 32767 (ms)
Da. 1 Operation pattern
0: Positioning termination
1: Continuous positioning control
2: Continuous path control
Da. 2 Control method
0: No control method,
1: 1-axis linear control (ABS)
2: 1-axis linear control (INC)
3: Speed.Position Ctrl. (Forward)
4: Speed.Position Ctrl. (Reverse)
5: Current value changing
Da. 3 ACC/DEC time
0 to 32767 (ms)
Da. 4 DEC/STOP time
0 to 32767 (ms)
Da. 5 Command speed
0 to 200000 (pulse/s)
Da. 6 Positioning address/movement
amount
0 to 2147483647 (pulse)
(For speed-position switching control)
Cd. 8 ACC/DEC time at speed
change 0 to 32767 (ms)
Cd. 9 DEC/STOP time at speed
change 0 to 32767 (ms)
Correct " Da. 6 Positioning
address/movement amount" (Refer to
Section 9.1.2).
Da. 6 Positioning address/movement
amount
-2147483648 to 2147483647 (pulse)
(For position control)
Refer to "Section 4.5 List of positioning data".
Da. 6 Positioning address/movement
amount
0 to 2147483647 (pulse)
(For speed-position switching control)
Correct " Da. 6 Positioning
address/movement amount" (Refer to
Section 9.1.2).