
97
97
SRK-C
(2) The operation data are applied to the 220 V or 240 V districts respectively.
(3) Limitation of Voltage application
Minimum: 198 V
Maximum: 264 V
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, (when it is less than 10 m, add 10 g refrigerant per meter and when it is 10 to 15 m, add 30 g refrigerant per meter.)
(5) Expressed in sound pressure level.
Notes (1) The data are measured at the following conditions.
Model SRK561CENF-L (Indoor unit)
SRC561CENF-L (Outdoor unit)
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27
°
C
19
°
C
35
°
C
24
°
C
JIS C9612, ISO-T1
Item
Model
SRK561CENF-L
SRC561CENF-L
Cooling capacity
(1)
W
5000/5000
Power source
1 Phase, 220/240V, 50 Hz
Cooling input
kW
2.08/2.18
Running current (Cooling)
A
10.2/9.53
Inrush current
A
44/48
COP (In cooling)
2.40/2.29
Noise level
(5)
dB (A)
45/45
53/54
Exterior dimensions
mm
275
×
790
×
189
615
×
850
×
290
+
30
Height
×
Width
×
Depth
Color
Ivory white
Polar white
Net weight
kg
9
52
Refrigerant equipment
–
RM5526GNE4 (Rotary type)
×
1
Compressor types & Q’ty
Motor
kW
–
1.9
Starting method
–
Line starting
Heat exchanger
Louver fins & tubing
Refrigerant control
Capillary tubes
Refrigerant
(4)
kg
R22 1.35
Refrigerant oil
R
0.7 (BARREL FREEZE 32SAM)
Air handling equipment
Tangential fan
×
1
Propeller fan
×
1
Fan type & Q’ty
Motor
W
23
40
Air flow (at High)
CMM
12/12
34/34
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Wireless-Remote controller
–
Operation switch
Room temperature control
MC. Thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow),
–
ECONO (Orange), HI POWER (Green)
Safety equipment
–
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
O.D
mm (in)
Liquid line:
φ
6.35 (1/4") Gas line:
φ
12.7 (1/2")
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.4m
–
Gas line : 0.35m
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
2.5 m (3 cores with Earth)
Size
×
Core number
1.5 mm
2
×
3 cores (Including earth cable)
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Optional parts
–
Connection
wiring
Operation
data
(1)
Refrigerant
piping
Содержание SRRM40HENG-L
Страница 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Страница 52: ...50 SRK GZ MEMO ...
Страница 94: ...92 SRK H MEMO ...
Страница 104: ...102 102 SRK C MEMO ...
Страница 180: ...178 SCM HG 4room MEMO ...
Страница 222: ...220 SCM HG 2room MEMO ...
Страница 234: ...232 SCM CG 2room MEMO ...
Страница 266: ...SCM C 264 MEMO ...
Страница 406: ...404 FDT N C MEMO ...
Страница 442: ...440 FDEN H MEMO ...
Страница 470: ...468 FDEN C MEMO ...
Страница 504: ...502 FDKN H MEMO ...
Страница 580: ...578 FDR H MEMO ...
Страница 698: ...696 V MULTI Models FDR258 A 308 A ...
Страница 724: ...722 V MULTI MEMO ...
Страница 1094: ...1092 FDC HKXR MEMO ...