SCM-C
253
(2)
Drilling of holes and fixture sleeve (Option parts)
(a)
Drill a hole with ø65
whole core drill
(b)
Adjusting sleeve length
(c)
Install the sleeve
(Inserting sleeve)
(* *ln *Sealing plate)
Note (1) Drill a hall with incline of 5 degree from
indoor side to outdoor side.
Indoor side
Outdoor side
Cut off the sleeve
collar in case of
drawing piping
out to rear.
Cut off the sleeve
coolar that can be
seen from beneath
the unit.
Wall thickness
+ 1.5 cm
Indoor side
Outdoor side
Turn to
tighten
Paste
View of sleeve when installed
Inclined
flange
Sealing
plate
Sleeve
Indoor side
Outdoor side
(3)
Preparation of indoor unit
(a)
Mounting of connecting wires
(i)
Remove lid.
(ii)
Remove cover, terminal block cover.
(iii) Connect the connection wire securely to the terminal block.
Use cables for interconnection wiring to avoid loosening of the
wires. CENELEC code for cables Required field cables.
H05 RNR3G1.5 (Example)
H
Harmonized cable type
05
300/500 volts
R
Natural-and/or synth, rubber wire insulation
N
Polychloroprene rubber conductors insullation
R
Stranded core
3or5 Number of conductors
G
One conductor of the cable is the earth conductor (yellow/
green)
1.5
Section of copper wire (mm
2
)
1
Affix the connection wire securely to the terminal block. If the wire is not affixed completely, contact will be poor,
and it is dangerous as the terminal block may heat up and catch fire.
2
Take care not to confuse the terminal numbers for indoor and outdoor connections.
3
Affix the connection wire using the wiring clamp.
(iv) Attach the terminal bock cover.
(v)
Attach the lid.
(b)
Protective taping
(Protect the cable with tape at the section where the cable passes through the hole opened on the
wall.)
(c)
Forming of pipe
(Holding down the pipe at the root, change the pipe direction, extend it and adjust according to the
circumstance.)
Connecting Wiring
Earth
Wiring
Terminal
Terminal Block
Wiring Clamp
Terminal Block Cover
Lid
Cover
Pull the part marked while pushing
its part in the direction of allow so as
to dismount it. (Dismount or detach it
for each side).
Содержание SRRM40HENG-L
Страница 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Страница 52: ...50 SRK GZ MEMO ...
Страница 94: ...92 SRK H MEMO ...
Страница 104: ...102 102 SRK C MEMO ...
Страница 180: ...178 SCM HG 4room MEMO ...
Страница 222: ...220 SCM HG 2room MEMO ...
Страница 234: ...232 SCM CG 2room MEMO ...
Страница 266: ...SCM C 264 MEMO ...
Страница 406: ...404 FDT N C MEMO ...
Страница 442: ...440 FDEN H MEMO ...
Страница 470: ...468 FDEN C MEMO ...
Страница 504: ...502 FDKN H MEMO ...
Страница 580: ...578 FDR H MEMO ...
Страница 698: ...696 V MULTI Models FDR258 A 308 A ...
Страница 724: ...722 V MULTI MEMO ...
Страница 1094: ...1092 FDC HKXR MEMO ...