446
FDEN-C
Item
Model
FDEN308C
FDCP308CEN3
Nominal cooling capacity
(1)
W
7100
Power source
1 Phase, 220/240V, 50Hz
Cooling input
kW
3.22/3.37
Running current (Cooling)
A
14.9/15.3
Power factor (Cooling)
%
98/92
Inrush current (L.R.A)
A
95
Noise level
(4)
dB(A)
Hi:45 Lo:39
52
Exterior dimensions
mm
Unit 260
×
840
×
840
845
×
880
×
340
Height
×
Width
×
Depth
Panel 30
×
950
×
950
Net weight
kg
27
73
Refrigerant equipment
–
GT-A5534HN41
×
1
Compressor type & Q’ty
Motor
kW
–
2.5
Starting method
–
Line starting
Heat exchanger
Louver fins & inner grooved tubing
Slitted fines & bare tubing
Refrigerant control
–
Capillary tube
Refrigerant
R407C
Quantity
kg
Holding charged
1.63 [Pre-charged up to the piping length of 5m]
Refrigerant oil
r
–
1.45 (MA32)
High pressure control
–
Air handling equipment
Fan type & Q’ty
Multiblade centrifugal fan
×
4
Propeller fan
×
1
Motor
W
35
×
2
55
×
1
Starting method
Line starting
Line starting
Air flow (Standard)
CMM
Hi:16.5 Lo:11.5
58
Fresh air intake
Unavailable
–
Air filter, Q’ty
Polypropylene net
×
2 (washable)
–
Shock & vibration absorber
Rubber sleeve (for fan motor)
Rubber mount (for compressor)
Electric heater
W
–
33 (Crank case heater)
Operation control
Operation switch
Wireless remote control switch
– (Indoor unit side)
Room temperature control
Thermostat by electronics
–
Safety equipment
Internal thermostat for fan motor.
Internal thermostat for fan motor.
Frost protection thermostat.
Thermistor for discharge temperature.
High pressure switch for protection.
Installation data
mm
Liquid line:
φ
9.52 (3/8
″
) Gas line:
φ
15.88 (5/8
″
)
Refrigerant piping size
(in)
Connecting method
Flare piping
Drain hose
(Connectable with VP20)
–
Insulation for piping
Necessary (both Liquid & Gas lines)
Accessories
Mounting kit. Wireless remote controller.
Optional parts
Decorative Panel
Model FDENP308CEN-S
Operation data
(3)
FDENP308CEN-S
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
JIS B8616 “UNITARY AIR-CONDITIONERS”
(3) The operation data indicate when the air-conditioner is operated at 220/240V 50Hz.
(4) Indicates the value at mild mode.
Notes (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27˚C
19˚C
35˚C
24˚C
ISO-T1, JIS B8616
184
×
126
×
650
Содержание SRRM40HENG-L
Страница 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Страница 52: ...50 SRK GZ MEMO ...
Страница 94: ...92 SRK H MEMO ...
Страница 104: ...102 102 SRK C MEMO ...
Страница 180: ...178 SCM HG 4room MEMO ...
Страница 222: ...220 SCM HG 2room MEMO ...
Страница 234: ...232 SCM CG 2room MEMO ...
Страница 266: ...SCM C 264 MEMO ...
Страница 406: ...404 FDT N C MEMO ...
Страница 442: ...440 FDEN H MEMO ...
Страница 470: ...468 FDEN C MEMO ...
Страница 504: ...502 FDKN H MEMO ...
Страница 580: ...578 FDR H MEMO ...
Страница 698: ...696 V MULTI Models FDR258 A 308 A ...
Страница 724: ...722 V MULTI MEMO ...
Страница 1094: ...1092 FDC HKXR MEMO ...