SCM-C
260
7.6
MAINTENANCE DATA
7.6.1
Trouble shooting
(1)
Trouble shooting to be performed prior to exchanging PCB, (Printed circuit board) [Common to all models]
All the models described in this chapter are controlled by a microcomputer. When providing maintenance service to customers it
is necessary to understand the function controlled by a micro computer thoroughly, so as not to mistakenly identify correct operations
as mis-operations. It is also necessary to perform the following simple checks before conducting detailed checks or exchanging
printed circuit board.
Before exchanging Printed circuit board
Claim call from the user
Ascertain the nature of the claim.
Ascertain the operation status.
Is this nonsense claim?
Operate the unit.
Does the trouble occur again?
Temporarily turn off the power source
and turn it on again in about 1 min. and
turn the unit on again.
Does the trouble occur again?
Disconnect connectors and connect them
again.
Operate the unit again after confirming that the fuse
and the varistor equipped on PCB does not burn
out.
Does the trouble occur again?
Carry out checks according to detailed
check process (See later page)
NO
YES
YES
YES
YES
NO
NO
NO
Unit did not cool, etc.
¡
Is the power on?
¡
Is the thermostat setting correct?
(Not too high?)
¡
Is the unit in a timer operation?
¡
Does user understand function?
etc.
¡
Explain the function of the unit to user.
No need for PCB change
Check further the status when the trouble Occurred
(such as the timer of occurrence, power failures,
thunder, use status of other electrical appliance, etc).
Clarify the reason for the problem and explain it
thoroughly to the user.
No need for PCB change
Microcomputer runaway due to power source
conditions is a possible cause.
No need for PCB change
The cause is defective connector contact.
Содержание SRRM40HENG-L
Страница 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Страница 52: ...50 SRK GZ MEMO ...
Страница 94: ...92 SRK H MEMO ...
Страница 104: ...102 102 SRK C MEMO ...
Страница 180: ...178 SCM HG 4room MEMO ...
Страница 222: ...220 SCM HG 2room MEMO ...
Страница 234: ...232 SCM CG 2room MEMO ...
Страница 266: ...SCM C 264 MEMO ...
Страница 406: ...404 FDT N C MEMO ...
Страница 442: ...440 FDEN H MEMO ...
Страница 470: ...468 FDEN C MEMO ...
Страница 504: ...502 FDKN H MEMO ...
Страница 580: ...578 FDR H MEMO ...
Страница 698: ...696 V MULTI Models FDR258 A 308 A ...
Страница 724: ...722 V MULTI MEMO ...
Страница 1094: ...1092 FDC HKXR MEMO ...