SRK-GZ
¡
Hot keep M mode [During HI POWER operation (for 15 min.)]
S
SRK502Z-L
(iii) Continuous mode operation
(Temperature setting button on remote controller: Continuous)
Model
SRK25GZ-L1
SRK35GZ-L1
SRK502Z-L
Item
AUTO
HI
MED
LO
AUTO
HI
MED
LO
AUTO
HI
MED
LO
Inverter frequency
104Hz
98Hz
50Hz
98Hz
94Hz
58Hz
144rps
110rps
50rps
Indoor fan
6th speed
5th speed 4th speed
7th speed
5th speed 3rd speed
8th speed
7th speed 5th speed
Outdoor fan
ON
ON
5th speed
4th speed 2nd speed
Notes (1) In the continuous mode, the continuous heating operation is performed without adjustment of room temperature.
(2) Protective functions will be operated with priority even during the continuous mode operation.
(iv) Hot keep operation
If the hot keep operation is selected during the heating operation, the indoor blower is controlled based on the temperature
of the indoor unit heat exchanger (detected with Th2, indoor unit heat exchanger sensor) to prevent blowing of cool
wind.
¡
Normal mode (Normal heating operation, operation after HI POWER completion)
¡
Values of A, B
A
B
At 0 Hz command
22
25
Other than 0 Hz
17
19
command
Indoor heat exchanger temp. (˚C)
1st speed
2nd speed
3rd speed
4th speed
5th speed
6th speed
7th speed
¡
Normal mode (Normal heating operation, operation after HI POWER completion)
Indoor heat exchanger temp. (˚C)
¡
Values of A, B
A
B
At 0 Hz command
22
25
Other than 0 Hz
17
19
command
S
SRK25, 35GZ-L1
a
b
27.5 28 29.5
31.5
34
36
37.5
39
40
1st speed
2nd speed
3rd speed
4th speed
5th speed
6th speed
7th speed
8th speed
OFF
Indoor fan
Indoor fan
Note (1) Refer to the table shown above
right for the values A and B.
Note (1) Refer to the table
shown above right for
the values A and B.
Note (1) Refer to the table shown above
right for the values A and B.
¡
Hot keep M mode [During HI POWER operation (for 15 min.)]
Indoor heat exchanger temp. (˚C)
a
b
29
31
32
34
38
42
50
1st speed
2nd speed
3rd speed
4th speed
5th speed
6th speed
7th speed
8th speed
OFF
Indoor fan
Note (1) Refer to the table shown above
right for the values A and B.
Indoor heat exchanger temp. (˚C)
1st speed
Indoor fan
2nd speed
3rd speed
4th speed
5th speed
6th speed
7th speed
Содержание SRRM40HENG-L
Страница 1: ...MITSUBISHI DAIYA 2000 AIR CONDITIONING HEAT PUMP MACHINERY HANDBOOK ...
Страница 52: ...50 SRK GZ MEMO ...
Страница 94: ...92 SRK H MEMO ...
Страница 104: ...102 102 SRK C MEMO ...
Страница 180: ...178 SCM HG 4room MEMO ...
Страница 222: ...220 SCM HG 2room MEMO ...
Страница 234: ...232 SCM CG 2room MEMO ...
Страница 266: ...SCM C 264 MEMO ...
Страница 406: ...404 FDT N C MEMO ...
Страница 442: ...440 FDEN H MEMO ...
Страница 470: ...468 FDEN C MEMO ...
Страница 504: ...502 FDKN H MEMO ...
Страница 580: ...578 FDR H MEMO ...
Страница 698: ...696 V MULTI Models FDR258 A 308 A ...
Страница 724: ...722 V MULTI MEMO ...
Страница 1094: ...1092 FDC HKXR MEMO ...