11 - 32
11. OPTIONS AND PERIPHERAL EQUIPMENT
Type
Model
Length
[m]
Core size Number
of Cores
Characteristics of one core
(Note 2)
Finishing
OD [mm]
Wire model
Structure
[Wires/mm]
Conductor
resistance
[ /km]
Insulation
coating
OD d [mm]
(Note 1)
Motor
brake
cable
MR-BKS1CBL M-A1-L
2 to 10
AWG20
2
21/0.18
34.6
or less
1.35
4.7 0.1
HRZFEV-A(CL3) AWG20
2 cores
MR-BKS1CBL M-A2-L
2 to 10
MR-BKS1CBL M-A1-H
2 to 10
(Note 6)
AWG20
2
110/0.08
39.0
or less
1.37
4.5 0.3
(Note 4)
RMFES-A(CL3X) AWG20
2 cores
MR-BKS1CBL M-A2-H
2 to 10
MR-BKS2CBL03M-A1-L
0.3
AWG20
2
19/0.203
32.0
or less
1.42
(Note 3, 7)
J11B331 UL 10125
MR-BKS2CBL03M-A2-L
0.3
Note 1. d is as shown below.
Insulation sheath
Conductor
d
2. Standard OD. Max. OD is about 10% greater.
3. Purchase from Toa Electric Industrial
4. Purchase from Taisei
5. Taiyo Cabletec
6. These wire sizes assume that the UL-compliant wires are used at the wiring length of 10m.
7. This model is for a single wire. The color must be specified separately.
11.6 Molded-case circuit breakers, fuses, magnetic contactors
Always use one molded-case circuit breaker and one magnetic contactor with one servo amplifier. When using
a fuse instead of the molded-case circuit breaker, use the one having the specifications given in this section.
Servo amplifier
Molded-case circuit breaker
Fuse
(Note 2)
Magnetic
contactor
Current [A]
Voltage
AC [V]
(Note 1)
Class
Current [A]
Voltage
AC [V]
Not using power
factor improving
reactor
Using power factor
improving reactor
MR-JN-10A
30A frame 5A
30A frame 5A
10A
MR-JN-20A/10A1
30A frame 10A
30A frame 10A
240V
T
15A
300V
S-N10
MR-JN-40A/20A1
30A frame 15A
30A frame 10A
20A
Note 1. When not using the servo amplifier as a UL/CSA Standard compliant product, K5 class fuse can be used.
2. Be sure to use a magnetic contactor (MC) with an operation delay time of 80ms or less. The operation delay time is the time
interval between current being applied to the coil until closure of contacts.
Содержание MELSERVO-JN Series
Страница 31: ... 22 MEMO ...
Страница 49: ...2 6 2 INSTALLATION MEMO ...
Страница 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Страница 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 251: ...9 4 9 DIMENSIONS 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Страница 351: ...12 48 12 SERVO MOTOR MEMO ...
Страница 445: ...13 94 13 POSITIONING MODE MEMO ...