(2) Parameter of 4 or more digits
The following example gives the operation procedure to change the electronic gear numerator (command
pulse multiplication numerator) (parameter No. PA06) to "12345".
Press MODE once.
Press SET once.
The screen blinks.
Press SET once.
Setting of upper
2 digits
Press UP or DOWN to
change the setting.
Press SET once.
Enter the setting.
Press MODE once.
Press MODE once.
Setting of lower 3 digits
(The decimal point of the first digit is lit.)
Press MODE four times.
Press SET once.
Press UP or DOWN to choose parameter No. PA06.
To the initial screen
of setting for lower 3
To the initial screen
of setting for upper 2
To proceed to the next parameter, press the "UP" or "DOWN" button.
Press UP or DOWN to
change the setting.
Press SET once.