13 - 5
13. POSITIONING MODE
Device
Symbol
Connector
pin No.
Functions/Applications
I/O
division
Positioning
mode
CP
CL
Servo-on
SON
CN1-4
When SON is turned on, the power is supplied to the base circuit and
the servo amplifier is ready to operate (servo-on).
When SON is turned off, the power to the base circuit is shut off and
the servo motor coasts.
Set parameter No. PD01 to " 4 " to switch this signal on (keep
terminals connected) automatically in the servo amplifier.
DI-1
Reset
RES
When RES is turned on for 50ms or longer, an alarm can be
deactivated.
Some alarms cannot be deactivated by the reset (RES). Refer to
section 8.1.
Turning RES on in an alarm-free status shuts off the base circuit. The
base circuit is not shut off when " 1 " is set in parameter No.
PD20.
This device is not designed to make a stop. Do not turn it ON during
operation.
DI-1
Automatic
/manual
selection
MD0
CN1-3
Turning MD0 ON selects the automatic operation mode, and turning
it OFF selects the manual operation mode.
DI-1
Internal
torque limit
selection
TL1
The internal torque limit 2 (parameter No. PC14) becomes valid by
turning TL1 on.
The forward torque limit (parameter No. PA11) and the reverse
torque limit (parameter No. PA12) are always valid.
The smallest torque limit among the valid forward and reverse torque
limits is the actual torque limit value.
DI-1
(Note)
Input
device
Comparison between limit
values
Valid torque limit value
TL1
Forward
rotation
Reverse
rotation
0
Parameter
No. PA11
Parameter
No. PA12
1
Parameter
No. PC14
>
Parameter
No. PA11
Parameter
No. PA12
Parameter
No. PA11
Parameter
No. PA12
Parameter
No. PC14
<
Parameter
No. PA11
Parameter
No. PA12
Parameter
No. PC14
Parameter
No. PC14
Note. 0: off
1: on
Refer to section 3.6.1(4).
Temporary
stop/Restart
TSTP
Turning TSTP ON during automatic operation makes a temporary
stop.
Turning TSTP ON again makes a restart.
Forward rotation start (ST1) or Reverse rotation start (ST2) is ignored
if it is turned ON during a temporary stop.
When the automatic operation mode is changed to the manual
operation mode during a temporary stop, the movement remaining
distance is erased.
During a home position return or during JOG operation, Temporary
stop/ Restart input is ignored.
DI-1
Содержание MELSERVO-JN Series
Страница 31: ... 22 MEMO ...
Страница 49: ...2 6 2 INSTALLATION MEMO ...
Страница 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Страница 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 251: ...9 4 9 DIMENSIONS 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Страница 351: ...12 48 12 SERVO MOTOR MEMO ...
Страница 445: ...13 94 13 POSITIONING MODE MEMO ...