12 - 29
12. SERVO MOTOR
6. For the servo motor alone. The vibration direction is as shown in the figure. The value is the one at the part that indicates the
maximum value (normally the opposite-to-load side bracket). When the servo motor stops, fretting is likely to occur at the
bearing. Therefore, suppress the vibration to about half of the permissible value. Note that this does not apply to the servo
motor with a reduction gear.
Vibration
Y
X
Servo motor
Speed [r/min]
0 1000 2000 3000 4000 5000 6000 7000
10
100
1000
Vi
br
at
io
n
am
pl
itu
de
(b
ot
h
am
pl
itu
de
s)
[ m]
7. V-10 indicates that the amplitude of a servo motor alone is 10 m or less. The following figure shows the servo motor installation
position for measurement and the measuring position.
Measuring
position
Bottom
Top
Servo motor
8. For the servo motor alone.
(2) Torque characteristics
POINT
For the system where the unbalanced torque occurs, such as a vertical axis
system, the unbalanced torque of the machine should be kept at 70% or less
of the rated torque.
The torque characteristics shown in the following graph are for the servo motor itself. When the input power
supply specifications of the servo amplifier are 1-phase 230VAC, the torque characteristics are indicated by
heavy lines. Part of the torque characteristics are indicated by broken lines for the 1-phase 100VAC power
supply and by thin lines for the 1-phase 200VAC power supply.
[HF-KP053G1/G5/G7]
0
Torque [N m]
1000 2000 3000 4000 4500
Continuous
running region
Speed [r/min]
0
0.1
0.2
0.3
0.4
0.5
0.6
Short-duration
running region
[HF-KP13G1/G5/G7]
0
1000 2000 3000 4000 4500
Short-duration
running region
Speed [r/min]
0
0.2
0.4
0.6
0.8
1
1.2
To
rq
ue
[N
m
]
Continuous
running region
Short-duration
running region
[HF-KP23G1/G5/G7]
0
To
rq
ue
[N
m
]
Continuous
running region
Speed [r/min]
0
0.5
1
1.5
2
2.5
1000 2000 3000 4000 4500
Continuous
running region
Short-duration
running region
[HF-KP43G1/G5/G7]
0
Torque [N m]
Speed [r/min]
1000 2000 3000 4000 4500
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
Содержание MELSERVO-JN Series
Страница 31: ... 22 MEMO ...
Страница 49: ...2 6 2 INSTALLATION MEMO ...
Страница 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Страница 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 251: ...9 4 9 DIMENSIONS 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Страница 351: ...12 48 12 SERVO MOTOR MEMO ...
Страница 445: ...13 94 13 POSITIONING MODE MEMO ...