![Mitsubishi Electric MELSERVO-JN Series Скачать руководство пользователя страница 333](http://html.mh-extra.com/html/mitsubishi-electric/melservo-jn-series/melservo-jn-series_instruction-manual_1811804333.webp)
12 - 30
12. SERVO MOTOR
12.6.3 Electromagnetic brake characteristics
CAUTION
The electromagnetic brake is provided for preventing a drop at power failure or at
servo alarm occurrence during vertical drive, or for holding a shaft at stop. Do not
use it for normal braking (including braking at servo lock).
Before performing the operation, be sure to confirm that the electromagnetic brake
operates properly.
The operation time of the electromagnetic brake varies depending on the power
supply circuit being used. Be sure to check the operation delay time with an actual
machine.
The characteristics of the electromagnetic brake provided for the servo motor with an electromagnetic brake
are indicated below.
Servo motor
Item
HF-KP series
053B
G1/G5/G7
13B
G1/G5/G7
23B
G1/G5/G7
43B
G1/G5/G7
Type (Note 1)
Spring-loaded safety brake
Rated voltage (Note 4)
24VDC
0
-10%
Power consumption
[W]at20
6.3
7.9
Coil resistance (Note 6)
[ ]
91.0
73.0
Inductance (Note 6)
[H]
0.088
0.10
Brake static friction torque
[N m]
0.32
1.3
[oz in]
45.3
184
Release delay time (Note 2)
[s]
0.03
0.03
Braking delay time (Note 2)
[s] DC off
0.01
0.02
Permissible braking work
Per braking
[J]
5.6
22
Per hour
[J]
56
220
Brake looseness at servo motor shaft (Note 5)
[degrees]
2.5
1.2
Brake life (Note 3)
Number of
braking cycles
[times]
20000
20000
Work per braking
[J]
5.6
22
Selection example of surge
absorbers to be used (Note 7, 8)
For the suppressed
voltage 125V
TND20V-680KB
For the suppressed
voltage 350V
TND10V-221KB
Note 1. There is no manual release mechanism. Use a 24VDC power supply to release the brake electrically.
2. The value for initial ON gap at 20 (68 ).
3. Brake gap increases as the brake lining wears, but the gap is not adjustable. Therefore, the brake life is indicated
as the number of braking cycles available before the gap adjustment is required.
4. Always prepare the power supply exclusively used for the electromagnetic brake.
5. The above values are typical initial values and not guaranteed values.
6. These values are measured values and not guaranteed values.
7. Select the electromagnetic brake control relay properly, considering the characteristics of the electromagnetic brake
and surge absorber. When a diode is used as surge absorber, the electromagnetic braking time will be longer.
8. Manufactured by Nippon Chemi-Con Corporation.
Содержание MELSERVO-JN Series
Страница 31: ... 22 MEMO ...
Страница 49: ...2 6 2 INSTALLATION MEMO ...
Страница 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Страница 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 251: ...9 4 9 DIMENSIONS 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Страница 351: ...12 48 12 SERVO MOTOR MEMO ...
Страница 445: ...13 94 13 POSITIONING MODE MEMO ...