![Mitsubishi Electric MELSERVO-JN Series Скачать руководство пользователя страница 58](http://html.mh-extra.com/html/mitsubishi-electric/melservo-jn-series/melservo-jn-series_instruction-manual_1811804058.webp)
3 - 9
3. SIGNALS AND WIRING
(2) Timing chart
95ms
95ms
Ready (RD)
Reset (RES)
Servo-on (SON)
OFF
ON
OFF
ON
ON
OFF
Base circuit
OFF
ON
OFF
ON
10ms
5ms
10ms
10ms
5ms
10ms
5ms
10ms
(1 to 2s)
Servo-on (SON) accepted
Main circuit
Control circuit
Power supply
Yes (OFF)
No (ON)
Trouble (ALM)
1s
Power-on timing chart
(3) Forced stop
CAUTION
Configure a circuit which interlocks with an external emergency stop switch in order
to stop the operation immediately and shut off the power.
Configure a circuit that shuts off the main circuit power as soon as EM1 is turned off at a forced stop. When
EM1 is turned off, the dynamic brake is operated to stop the servo motor immediately. At this time, the
display shows the servo forced stop warning (E6.1).
During the normal operation, do not use the forced stop (EM1) to alternate stop and run. The service life of
the servo amplifier may be shortened.
Also, the servo motor rotates simultaneously with the reset of the forced stop if a forward rotation start
(ST1) or the reverse rotation start (ST2) is ON, or if a pulse train is input during the forced stop. Be sure to
shut off the operation instruction during the forced stop.
(Note)
Servo amplifier
DICOM
EM1
24VDC
Forced stop
Note. For sink I/O interface. For source I/O interface, refer to section 3.8.3.
Содержание MELSERVO-JN Series
Страница 31: ... 22 MEMO ...
Страница 49: ...2 6 2 INSTALLATION MEMO ...
Страница 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Страница 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 251: ...9 4 9 DIMENSIONS 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Страница 351: ...12 48 12 SERVO MOTOR MEMO ...
Страница 445: ...13 94 13 POSITIONING MODE MEMO ...