![Mitsubishi Electric MELSERVO-JN Series Скачать руководство пользователя страница 95](http://html.mh-extra.com/html/mitsubishi-electric/melservo-jn-series/melservo-jn-series_instruction-manual_1811804095.webp)
3 - 46
3. SIGNALS AND WIRING
(5) Only main circuit power supply off (control circuit power supply remains on)
Dynamic brake
Dynamic brake
Electromagnetic brake
Electromagnetic brake
Electromagnetic brake
operation delay time
10 to 60ms
Electromagnetic
brake interlock
(MBR)
Base circuit
Servo motor speed
Trouble (ALM)
Main circuit power
supply
Deceleration starts after the trouble (ALM) turns OFF. (Note 2)
Electromagnetic brake sequence output
(parameter No. PC09)
ON
OFF
ON
OFF
ON
OFF
No (ON)
Yes (OFF)
(Note 1)
(10ms)
Note 1. ON: Electromagnetic brake is not activated.
OFF: Electromagnetic brake is activated.
2. The operation differs from the timing chart of MR-J3- A servo amplifier.
3.11.4 Wiring diagrams (HF-KN series HF-KP G1/G5/G7 HG-KR G1/G5/G7 servo motor)
(1) When cable length is 10m or less
B1
B2
U
(Note 3)
Electromagnetic
brake interlock
(MBR)
AWG20
AWG20
MR-BKS1CBL M-A1-L
MR-BKS1CBL M-A2-L
MR-BKS1CBL M-A1-H
MR-BKS1CBL M-A2-H
(Note 1)
Trouble
(ALM)
Servo motor
10m or less
(Note 5)
RA
(Note 2)
B
24VDC power
supply for
electromagnetic
brake
Note 1. Connect a surge absorber as close to the servo motor as possible.
2. There is no polarity in electromagnetic brake terminals (B1 and B2).
3. When using a servo motor with an electromagnetic brake, always assign the electromagnetic brake
interlock (MBR) to CN1-12 pin by parameter No. PD18.
4. Do not use the 24VDC interface power supply for the electromagnetic brake.
5. Switch off the circuit interlocking with the emergency stop switch.
When fabricating the motor brake cable MR-BKS1CBL M-H, refer to section 11.1.4.
Содержание MELSERVO-JN Series
Страница 31: ... 22 MEMO ...
Страница 49: ...2 6 2 INSTALLATION MEMO ...
Страница 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Страница 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 251: ...9 4 9 DIMENSIONS 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Страница 351: ...12 48 12 SERVO MOTOR MEMO ...
Страница 445: ...13 94 13 POSITIONING MODE MEMO ...