4 - 17
4. PARAMETERS
(2) For output division ratio setting
Set parameter No. PC13 to " 1 ".
The number of pulses per servo motor revolution is divided by the set value.
Output pulse= Resolution per servo motor revolution
Setting valve
[pulse/rev]
For instance, when parameter No. PA15 is set to "8", the A/B-phase pulses actually output are as indicated
below.
A/B-phase output pulses = 131072
8 ꞏ
1
4 = 4096 [pulse]
Servo motor
Encoder
A-phase/B-phase
output pulses
Feedback pulses
M
ENR
1
Set division ratio by parameter No. PA15.
(3) When outputting pulse same as command pulses
Set parameter No. PC13 to " 2 ". The feedback pulses from the encoder can be output after being
converted to the same value as the command pulse.
CDV
CMX
Servo motor
Encoder
A-phase/B-phase
output pulses
Feedback pulses
M
FBP conversion
Deviation counter
Pulse conversion
Both equivalent.
Electronic gear
Command
input pulses
Содержание MELSERVO-JN Series
Страница 31: ... 22 MEMO ...
Страница 49: ...2 6 2 INSTALLATION MEMO ...
Страница 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Страница 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 251: ...9 4 9 DIMENSIONS 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Страница 351: ...12 48 12 SERVO MOTOR MEMO ...
Страница 445: ...13 94 13 POSITIONING MODE MEMO ...