6 - 4
6. GENERAL GAIN ADJUSTMENT
(2) Performing the one-touch tuning
Select the response mode in (1), and press the "AUTO" button to start the one-touch tuning.
When the progress of the one-touch tuning reaches 100%, the parameters adjusted
automatically in the one-touch tuning are written into the servo amplifier.
The progress of the one-touch tuning is displayed from 0 to 100%.
During the one-touch tuning, the decimal point is lit, moving from right to left.
Pressing the "MODE" button during the one-touch tuning calls the status display.
During the one-
touch adjustment
At 100%
Completion display
Settling time display
2s later
Settling time (100ms)
The settling time of the status display is displayed, and the value is displayed 2s later.
The "UP" and "DOWN" buttons enable to call other status displays, and the "MODE"
button enables to call the diagnostic mode.
Pressing any button calls the settling time (status display).
The completion display is called 1s later.
At completion, "Fin" blinks regardless of the item displayed.
POINT
The settling time can also be checked in the status display mode. (Refer to
section 5.3.)
Содержание MELSERVO-JN Series
Страница 31: ... 22 MEMO ...
Страница 49: ...2 6 2 INSTALLATION MEMO ...
Страница 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Страница 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Страница 251: ...9 4 9 DIMENSIONS 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Страница 351: ...12 48 12 SERVO MOTOR MEMO ...
Страница 445: ...13 94 13 POSITIONING MODE MEMO ...