6 OPTIONS AND PERIPHERAL EQUIPMENT
6.3 MR-CM simple converter
External interface
Example of configuration including peripheral equipment
For mounting CNP1 and CNP2 to the servo amplifier, use daisy chain power connectors. Do not use the connector set
supplied with the servo amplifier.
Page 172 List of cable/connector sets
■
Restrictions
• When closely mounting multiple servo amplifiers, the servo amplifier on the right must have a larger depth than that on the
left. Otherwise, the CNP1, CNP2, and CNP3 connectors cannot be removed.
• When installing a servo amplifier on the left that is deeper than the servo amplifier on the right without close mounting,
leave at least 15 mm of clearance between the servo amplifiers.
*1 Do not remove dummy pins or wires attached to CNP2 connectors.
*2 To detach a CNP2 connector when servo amplifiers are closely mounted, detach the CN3 connector of the servo amplifier on the left
side before detaching the CNP2 connector.
*3 For the wires between the simple converter and a servo amplifier and between each servo amplifier, twist or bundle them with cable ties
to keep the two wires close to each other. Also, total wiring length from P4/N- of the simple converter to P4/N- of the servo amplifier
should be 5 m or less.
L1
L2
L3
N-
N-
P4
MCCB
MC
L1
L2
L3
N-
P4
T1
T2
P4
L11
L21
*3
*3
L11
L21
N-
N-
P4
P4
L11
L21
L11
L21
CNP1
CNP1
CNP1
CNP2
*1 *2
CNP2
*1 *2
CNP2
CN10
CNP3
CNP3
Power supply
EMC filter
Simple converter
Servo amplifier
Servo amplifier
Power factor
improving
AC reactor
Line noise