266
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.17 MR-J3-D05 safety logic unit
Interface
For the MR-J3-D05, source type I/O interfaces can be used.
■
Sink I/O interface (CN9, CN10 connectors)
• Digital input interface DI-1
This is an input circuit in which the photocoupler cathode side is the input terminal. Transmit signals from a sink (open-
collector) type transistor output, relay switch, etc.
• Digital output interface DO-1
This is a circuit in which the collector of the output transistor is the output terminal. When the output transistor is turned on, the
current flows to the collector terminal.
A lamp, relay, or photocoupler can be driven. Install a diode (D) for an inductive load, or install an inrush current suppressing
resistor (R) for a lamp load. (Rated current: 40 mA or less, maximum current: 50 mA or less, inrush current: 100 mA or less) A
maximum of 2.6 V voltage drop occurs internally.
*1 If the voltage drop (maximum of 2.6 V) interferes with the relay operation, apply high voltage (maximum of 26.4 V) from external source.
V
CES
≤
1.0 V
I
CEO
≤
100
μ
A
TR
200 mA
MR-J3-D05
Approx. 5.4 k
Ω
Approximately
5 mA
Switch
For transistor
SRESA-,
etc.
SRESA+,
etc.
24 V DC ± 10 %
MR-J3-D05
200 mA
If polarity of diode is
reversed, MR-J3-D05
will malfunction.
SDO2B+,
etc.
SDO2B-,
etc.
Load
24 V DC ± 10 %
*1
Содержание MELSERVO-J5 MR-J5-G Series
Страница 1: ...MR J5 User s Manual Hardware MR J5 _G_ MR J5W_ _G_ MR J5 _A_ Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 473: ...12 USING A FULLY CLOSED LOOP SYSTEM 12 7 Absolute position detection system 471 12 MEMO ...
Страница 477: ......