6 OPTIONS AND PERIPHERAL EQUIPMENT
6.2 Regenerative option
183
6
■
Calculation of regenerative energy per cycle
As an example, calculate the regenerative energy in the following operation pattern with MR-J5W3-_G_ servo amplifier.
Calculate the energy at each timing in one cycle. Energy is a positive value in power running and a negative value in
regeneration. Create a table like the one shown below, and write down the energy during power running/regeneration with
signs.
Calculate the energy consumed by the regenerative resistor ER [J] with the following formula for the calculation results from
E1 to E11 with negative values.
When the absolute value of the value in E1 to E11 is assumed to be Es: ER [J] =
η
m
• E
s
- E
c
If ER values are negative at all timings, the regenerative option is not needed. If the values of ER include positive values, from
the total of ERs whose subtraction results are positive and one-cycle period, the power consumption PR [W] of the
regenerative resistor can be calculated with the following equation.
PR [W] = total of positive ERs/one-cycle operation period (tf)
The regenerative option is not required when the PR value is equal to or less than the specification value for the built-in
regenerative power of the servo amplifier.
Timing
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
A-axis
E1A
E2A
E3A
E4A
E5A
E6A
E7A
E8A
E9A
E10A
E11A
B-axis
E1B
E2B
E3B
E4B
E5B
E6B
E7B
E8B
E9B
E10B
E11B
C-axis
E1C
E2C
E3C
E4C
E5C
E6C
E7C
E8C
E9C
E10C
E11C
Sum
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
Servo motor speed
tf (one cycle)
tf (one cycle)
A-axis
Time
B-axis
Time
C-axis
Time