5 CHARACTERISTICS
5.3 Dynamic brake characteristics
165
5
Permissible load to motor inertia when the dynamic brake is used
Use the dynamic brake under the load to motor inertia ratio indicated in the following table. If the ratio is higher than this value,
the dynamic brake may burn. If the ratio exceeds the value, contact your local sales office.
The values of the permissible load to motor inertia ratio in the table are the values at the maximum speed of the servo motor.
■
200 V class
Series
Model
Permissible load to motor inertia ratio
[multiplier]
HK-KT
HK-KT053W
34
HK-KT13W
34
HK-KT13UW
10
HK-KT1M3W
25
HK-KT23W
23 (when 6000 r/min or less: 28)
HK-KT23UW
10
HK-KT43W
23
HK-KT43UW
10
HK-KT63W
30
HK-KT7M3W
20
HK-KT7M3UW
10
HK-KT103W
20
HK-KT103UW
20
HK-KT153W
30
HK-KT203W
30
HK-KT202W
30
HK-KT434W
30
HK-KT634W
30
HK-KT7M34W
20
HK-KT1034W
30
HK-KT1534W
30
HK-KT2034W
30
HK-KT2024W
30
HK-ST
HK-ST52W
15 (when 3000 r/min or less: 19)
HK-ST102W
23
HK-ST172W
30
HK-ST202AW
30
HK-ST202W
15 (when 3000 r/min or less: 20)
HK-ST302W
30
HK-ST352W
12 (when 3000 r/min or less: 22)
HK-ST502W
10
HK-ST702W
8
HK-ST524W
15
HK-ST1024W
40
HK-ST1724W
40
HK-ST2024AW
20
HK-ST2024W
38
HK-ST3024W
30
HK-ST3524W
44
HK-ST5024W
23
HK-ST7024W
22